25-PIN CABLE ELECTRICAL CONNECTIONS

5 25-PIN CABLE ELECTRICAL CONNECTIONS
All DS4800 models are equipped with a cable terminated by a 25-pin male D-sub connector
for connection to the power supply and input/output signals. The details of the connector pins
are indicated in the following table.
Pin
Name
13, 9
Vdc
25, 7
GND
1
CHASSIS
18
I1A
19
I1B
6
I2A
10
I2B
8
O1+
22
O1-
11
O2+
12
O2-
20
RX
21
TX
23
ID+
24
ID-
14, 15, 16, 17 NC
Pin
2
3
MAIN INTERFACE
(SW SELECTABLE)
4
5
* Do not leave floating, see par. 5.2.2 for connection details.
1
14
Figure 44 - 25-pin Male D-sub Connector
25-pin D-sub male connector pinout
Function
Power supply input voltage +
Power supply input voltage -
Cable shield connected to chassis
External Trigger A (polarity insensitive)
External Trigger B (polarity insensitive)
Input 2 A (polarity insensitive)
Input 2 B (polarity insensitive)
Output 1 +
Output 1 -
Output 2 +
Output 2 -
Auxiliary Interface RX
Auxiliary Interface TX
ID-NET™ network +
ID-NET™ network -
Not Connected
Name
RS232
TX
RX
RTS
CTS
13
25
RS485
Full-Duplex
TX+
*RX+
TX-
*RX-
5
RS485
Half-Duplex
RTX+
RTX-
51