Installation

3.1.3 Mounting Location

The inverters are designed for indoor and outdoor installation (IP65), to increase
the safety, performance and lifespan of the inverter, please select
the mounting location carefully based on the following rules:
• The inverter should be installed on a solid surface, far from flammable or
corrosion materials, where is suitable for inverter's weight and dimensions.
• The ambient temperature should be within -25℃ ~ 60℃ (between -13 °F and
140°F).
• The installation of inverter should be protected under shelter. Do not expose
the inverter to direct sunlight, water, rain, snow, spray lightning, etc.
The inverter should be installed vertically on the wall, or lean back on plane
with a limited tilted angle. Please refer to below picture.
Max
<30°
>0°