Parts Listing (Netbay Console Switch); Netbay Power Distribution Units; Netbay Rack Power Distribution Unit Introduction - IBM 9306 Hardware Maintenance Manual

Hide thumbs Also See for 9306:
Table of Contents

Advertisement

10. Route the console cable set toward the rear of your rack cabinet, and up or
11. Connect the other end of the console cable set to the appropriate monitor,
12. Repeat step 9 to 11 for all servers that you need to connect to your console
13. Connect the power cord that comes with the console switch to the power
14. Route the power cord toward the rear of your rack cabinet, and either up or
15. Refer to the Apex User Guide CD for configuration and operation information

Parts listing (NetBAY Console Switch)

NetBAY Power Distribution Units

The IBM NetBAY Rack Power Distribution Units are part of the Rack Modular Power
Distribution Unit (M/PDU) family.
These Rack PDUs are used in all models of the IBM 9306 and 9308 racks.
The Rack PDUs come in three types:
v NetBAY Rack Power Distribution Unit
v NetBAY Front-end Power Distribution Unit
v NetBAY Server Dual-cord Power Distribution Unit

NetBAY rack Power Distribution Unit introduction

The IBM NetBAY Rack Power Distribution Unit is part of the Rack Modular Power
Distribution Unit (M/PDU) family and enables you to connect up to seven devices to
a single dedicated power source, such as an electrical outlet or an uninterruptable
power supply (UPS). The Rack PDU has one power inlet and seven IEC standard
130
Hardware Maintenance Manual: IBM PC Server/Enterprise Racks Types 9306, 9308
9. Connect one end of a console cable set to one of the numbered ports on the
rear of the console switch.
down toward your server. Use the cable straps that come with this option to
secure the console cable set along the way.
mouse, and keyboard connectors on your server.
switch.
connector on the rear of the console switch.
down toward a properly wired and grounded power source such as an
uninterruptable power supply (UPS), a power distribution unit (PDU), or an
electrical outlet. Use the cable straps that come with this option to secure the
power cord along the way, and use the openings in your rack cabinet if you
must exit the rack to connect to your power source.
about your console switch.
NetBAY (Console Switch)
1x4 switch
2x8 switch
7-foot locking console cable
12-foot locking console cable
FRU
06P6003
06P6004
06P6006
06P6007