  • Page 1 Power Systems Adapter placement for the 9040-MR9...
  • Page 2 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 17, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ®...
  • Page 3: Table Of Contents

    Contents Safety notices......................v Adapter placement....................1 Adapter placement rules and slot priorities for the 9040-MR9 ..............1 Adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I/O expansion drawer....7 Related procedures for adapter placement....................15 Finding the current system configuration in IBM i................15 Notices........................17...
  • Page 4 iv  ...
  • Page 5: Safety Notices

    Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der Bildschirmarbeitsverordnung geeignet. Laser safety information IBM servers can use I/O cards or features that are fiber-optic based and that utilize lasers or LEDs. Laser compliance IBM servers may be installed inside or outside of an IT equipment rack.
  • Page 6 • Each rack cabinet might have more than one power cord. – For AC powered racks, be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing. vi  Power Systems: Adapter placement for the 9040-MR9...
  • Page 7 – For racks with a DC power distribution panel (PDP), turn off the circuit breaker that controls the power to the system unit(s), or disconnect the customer’s DC power source, when directed to disconnect power during servicing. • Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet.
  • Page 8 (for example, when working from a ladder). Stability hazard: • The rack may tip over causing serious personal injury. • Before extending the rack to the installation position, read the installation instructions. viii  Power Systems: Adapter placement for the 9040-MR9...
  • Page 9 • Do not put any load on the slide-rail mounted equipment mounted in the installation position. • Do not leave the slide-rail mounted equipment in the installation position. (L002) (L003) Safety notices  ix...
  • Page 10 There are no serviceable parts inside the device. • Use of the controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure. (C026) x  Power Systems: Adapter placement for the 9040-MR9...
  • Page 11 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
  • Page 12 Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
  • Page 13 The dc-powered system employs an isolated DC return (DC-I) design. The DC battery return terminal shall not be connected to the chassis or frame ground. The dc-powered system is intended to be installed in a common bonding network (CBN) as described in GR-1089-CORE.
  • Page 14 Systems: Adapter placement for the 9040-MR9...
  • Page 15: Adapter Placement

    9040-MR9 system. Slot descriptions for the 9040-MR9 The 9040-MR9 systems provide PCIe3 and PCIe4 slots. The 9040-MR9 systems offer two or four POWER9 processor modules. The PCIe slots are enabled to support the PCIe3 cable adapter (FC EJ08 or FC EJ20) that is used to attach the EMX0 PCIe Gen3 I/O expansion drawer.
  • Page 16 If your system does not have Linux partitions, the I/O Adapter Enlarged Capacity setting should be disabled. Note the following: • The I/O cassettes that are used in the 9040-MR9 system can hold half length, full height and half length, half height PCIe adapters. • All PCIe slots support the single root I/O virtualization (SR-IOV) function.
  • Page 17 Adapter placement rules Use this information while selecting slots for installing adapters in the 9040-MR9 system. Use Table 4 on page 3 to identify adapter slot placement priorities and maximums for the system. • P1-C9 and P1-C12 are general-purpose slots that are also designated as serial-attached SCSI (SAS) controller slots for controlling the internal disk bays.
  • Page 18 Table 4. Adapter slot priorities and maximum adapters supported in the 9040-MR9 (continued) Feature code Description Slot priority Maximum number of adapters supported 2 processors 3 processors 4 processors 5735 8 Gb PCI Express 12, 9,11,8, 10, 7 12, 9, 11, 8, 5, 10, 7, 4...
  • Page 19 Table 4. Adapter slot priorities and maximum adapters supported in the 9040-MR9 (continued) Feature code Description Slot priority Maximum number of adapters supported 2 processors 3 processors 4 processors EC65 PCIe4 x16 2-Port EDR 11, 8, 10, 7 11, 8, 5, 10, 7, 4...
  • Page 20 Table 4. Adapter slot priorities and maximum adapters supported in the 9040-MR9 (continued) Feature code Description Slot priority Maximum number of adapters supported 2 processors 3 processors 4 processors EJ32 4767-001 11, 8, 10, 7, 12, 9 11, 8, 5, 10, 7, 4, 12, 9...
  • Page 21: Adapter Placement Rules And Slot Priorities For The Emx0 Pcie Gen3 I/O Expansion Drawer

    Table 4. Adapter slot priorities and maximum adapters supported in the 9040-MR9 (continued) Feature code Description Slot priority Maximum number of adapters supported 2 processors 3 processors 4 processors EN1G PCIe3 8x 2-port Fibre 11, 8, 10, 7, 12, 9...
  • Page 22 P1-C1 PCIe3 x16 P1-C2 PCIe3 x8 P1-C3 PCIe3 x8 P1-C4 PCIe3 x16 P1-C5 PCIe3 x8 P1-C6 PCIe3 x8 P2-C1 PCIe3 x16 P2-C2 PCIe3 x8 P2-C3 PCIe3 x8 P2-C4 PCIe3 x16 P2-C5 PCIe3 x8 8  Power Systems: Adapter placement for the 9040-MR9...
  • Page 23 Note: You can click the link that appears in the feature code column for more technical information specific to the adapter. • If the EMX0 PCIe3 expansion drawer is configured with two PCIe3 6-slot fanout modules, distribute the adapters across both I/O modules whenever possible. Adapter placement for the 9040-MR9  9...
  • Page 24 P1-C2, P2-C2, P1- 2 or 6 2 or 6 2 or 6 SR/Cu adapter (FC EC2R and C5, P2-C5, P1-C3, EC2S; CCIN 58FA); Adapter part P2-C3, P1-C6, P2- number: 01FT759 C6, P1-C1, P2-C1, P1-C4, P2-C4 10  Power Systems: Adapter placement for the 9040-MR9...
  • Page 25 P2-C3, P1-C6, P2-C6 number: 00MH959 EJ14 PCIe3 12 GB Cache RAID PLUS P1-C1, P2-C1, P1- SAS adapter quad-port 6 Gb x8 C4, P2-C4, P1-C3, (FC EJ14; CCIN 57B1); Adapter P2-C3, P1-C6, P2-C6 part number 01DH742 Adapter placement for the 9040-MR9  11...
  • Page 26 PCIe3 16 Gb 2-port Fibre P1-C1, P2-C1, P1- 6 (EL5B - 6 (EL5B - Channel adapter (FC EL5B and C4, P2-C4, P1-C2, EN0A; CCIN 577F); Adapter part P2-C2, P1-C3, P2- number: 00E3496 C3, P1-C5, P2-C5, P1-C6, P2-C6 12  Power Systems: Adapter placement for the 9040-MR9...
  • Page 27 00E2715; low-profile C3, P1-C5, P2-C5, tailstock: 00E2720 P1-C6, P2-C6 EN0W PCIe2 2-port 10 GbE BaseT P1-C1, P2-C1, P1- 6 (EL55 - 0) 6 RJ45 Adapter C4, P2-C4, P1-C2, P2-C2, P1-C3, P2- C3, P1-C5, P2-C5, P1-C6, P2-C6 Adapter placement for the 9040-MR9  13...
  • Page 28 P1-C6, P2-C6 EN1J PCIe4 x8 2-port Fibre Channel P1-C2, P2-C2, P1- (32 Gb/s); (FC EN1J and C5, P2-C5, P1-C3, EN1K; CCIN 579C); Adapter part P2-C3, P1-C6, P2- number: 02CM909 C6, P1-C1, P2-C1, P1-C4, P2-C4 14  Power Systems: Adapter placement for the 9040-MR9...
  • Page 29: Related Procedures For Adapter Placement

    About this task To find the current system configuration, start an IBM i session and sign on. If you have more than one system, start a session on the system that is being upgraded and for which you have service tools authority.
  • Page 30 11. Press F12 to return to the previous window. 12. Do you have an expansion unit attached? • No: Go to “Adapter placement rules and slot priorities for the 9040-MR9” on page 1. • Yes: Do the following tasks: a. Type 9 for the System Expansion Unit field and press Enter.
  • Page 31: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 32: Accessibility Features For Ibm Power Systems Servers

    This product uses standard navigation keys. Interface information The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power Systems servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 33: Privacy Policy Considerations

    Contact the vendor for accessibility information about its products. Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
  • Page 34 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 35 Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A. Japan Electronics and Information Technology Industries Association (JEITA) Notice This statement applies to products less than or equal to 20 A per phase. This statement applies to products greater than 20 A, single phase.
  • Page 36 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 37: Class B Notices

    Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 38 This statement applies to products less than or equal to 20 A per phase. This statement applies to products greater than 20 A, single phase. This statement applies to products greater than 20 A per phase, three-phase. Japan Voluntary Control Council for Interference (VCCI) Notice 24  Power Systems: Adapter placement for the 9040-MR9...
  • Page 39: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 40 IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed. You may not download, export or re-export this information except in full compliance with all applicable laws and regulations, including all United States export laws and regulations.
  • Page 42 IBM®...