5.
Reliable earthing (grounding) — Maintain reliable
grounding of rack-mounted equipment. Pay particular
attention to supply connections other than direct
connections to the branch circuit (such as the use of power
strips).

Rack mounting procedure

These distribution amplifiers can be mounted on any of the
following rack shelves:
RSF 123 (part # 60-190-20) 1U 3.5" VersaTools
RSB 123 (part # 60-604-21) 1U 3.5" VersaTools basic rack shelf
RSU 126 (part # 60-190-10) 1U 6" rack shelf kit
RSB 126 (part # 60-604-11) 1U 6" basic rack shelf
RSU 129 (part # 60-190-01) 1U 9.5" rack shelf kit
RSB 129 (part # 60-604-02) 1U 9.5" basic rack shelf
1U Universal Rack Shelf
Front false
faceplate
uses 2
screws.
Use 2 mounting holes on
opposite corners.
Rack mounting the DVI DA2 or DVI DA4
To mount the distribution amplifier on a rack shelf:
1.
If necessary, remove rubber feet from the bottom of the
unit.
2.
Align two diagonally opposite mounting holes on the
unit with two pre-drilled holes in the shelf. Use the two
provided 4-40 x 3/16" screws to secure the unit on the
shelf.
3.
Install other unit(s) or false faceplate(s) on the rack shelf.
DVI DA2 and DVI DA4 • Installation and Operation
® rack shelf kit
1/2 Rack Width Front False
Faceplate
(2) 4-40 x 3/16"
Screws
2-3