RX − 8801 SA / JE
5) TIE (Timer Interrupt Enable) bit
When a fixed-cycle timer interrupt event occurs (when the TF bit value changes from "0" to "1"), this bit's value
specifies whether an interrupt signal is generated (/INT status changes from Hi-Z to low) or is not generated (/INT
status remains Hi-Z).
TIE
Write/Read

8.3.3. Fixed-cycle timer interrupt interval (example)

Timer
Counter
setting
0
1
2
41
205
410
2048
4095
• Time error in fixed-cycle timer
A time error in the fixed-cycle timer will produce a positive or negative time period error in the selected
source clock. The fixed-cycle timer's time is within the following range relative to the time setting.
(Fixed-cycle timer's time setting (∗) − source clock period) to (timer's time setting)
∗ The time actually set to the timer is adjusted by adding the time described above to the
communication time for the serial data transfer clock used for the setting.

8.3.4. Fixed-cycle timer start timing

Counting down of the fixed-cycle timer value starts at the rising edge of the SCL signal that occurs when the TE value
is changed from "0" to "1" (after bit 0 is transferred).
SCL pin
SDA pin
Internal timer
/INT pin
Data
1) When a fixed-cycle timer interrupt event occurs, an interrupt signal is not
generated or is canceled (/INT status remains Hi-Z).
2) When a fixed-cycle timer interrupt event occurs, the interrupt signal is
0
canceled (/INT status changes from low to Hi-Z).
Even when the TIE bit value is "0" another interrupt event may change the /INT status to low (or
may hold /INT = "L").
When a fixed-cycle timer interrupt event occurs, an interrupt signal is
generated (/INT status changes from Hi-Z to low).
1
When a fixed-cycle timer interrupt event has been generated low-level output from the /INT pin
occurs only when the value of the control register's TIE bit is "1". Up to 7.8 ms after the interrupt
occurs, the /INT status is automatically cleared (/INT status changes from low to Hi-Z).
4096 Hz
64 Hz
TSEL1,0 = 0,0
TSEL1,0 = 0,1
244.14 μ s
15.625 ms
488.28 μ s
10.010 ms
640.63 ms
50.049 ms
3.203 s
100.10 ms
6.406 s
500.00 ms
32.000 s
0.9998 s
63.984 s
∗ ) The timer's time setting = source clock period × timer counter's division value.
Address D
TE
FSEL0
FSEL1
TSEL1
Description
Source clock
"Second"
update
TSEL1,0 = 1,0
1 s
31.25 ms
2 s
41 s
205 s
410 s
2048 s
4095 s
ACK
TSEL0
Operation of timer
Page - 16
"Minute"
update
TSEL1,0 = 1,1
1 min
2 min
41 min
205 min
410 min
2048 min
4095 min
ETM26E-03