RX − 8801 SA / JE

8.3.2. Related registers for function of time update interrupts.

Address
B
Timer Counter 0
C
Timer Counter 1
D
Extension Register
E
Flag Register
F
Control Register
∗1)
"o" indicates write-protected bits. A zero is always read from these bits.
∗2)
Bits marked with "•" are RAM bits that can contain any value and are read/write-accessible.
∗ Before entering settings for operations, we recommend writing a "0" to the TE and TIE bits to prevent hardware
interrupts from occurring inadvertently while entering settings.
∗ When the STOP bit or RESET bit value is "1" the time update interrupt function operates only partially.
(Operation continues if the source clock setting is 4096 Hz. Otherwise, operation is stopped.)
∗ When the fixed-cycle timer interrupt function is not being used, the fixed-cycle timer control register (Reg – B to C)
can be used as a RAM register. In such cases, stop the fixed-cycle timer function by writing "0" to the TE and TIE
bits.
1) TSEL0,1 bits (Timer Select 0, 1)
The combination of these two bits is used to set the countdown period (source clock) for the fixed-cycle timer
interrupt function (four settings can be made).
TSEL0,1
Write/Read
∗1) The /INT pin's auto reset time (tRTN) varies as shown above according to the source clock setting.
∗2) When the source clock has been set to "second update" or "minute update", the timing of both
countdown and interrupts is coordinated with the clock update timing.
2) Fixed-cycle Timer Control register (Reg - B to C)
This register is used to set the default (preset) value for the counter. Any count value from 1 (001 h) to
4095 (FFFh) can be set. The counter counts down based on the source clock's period, and when the count value
changes from 001h to 000h, the TF bit value becomes "1".
The countdown that starts when the TE bit value changes from "0" to "1" always begins from the preset value.
Be sure to write "0" to the TE bit before writing the preset value. If a value is written while TE = "1" the first
subsequent event will not be generated correctly.
bit 7
bit 6
3) TE (Timer Enable) bit
This bit controls the start/stop setting for the fixed-cycle timer interrupt function.
TE
Write/Read
4) TF (Timer Flag) bit
If set to "0" beforehand, this flag bit's value changes from "0" to 1" when a fixed-cycle timer interrupt event has
occurred. Once this flag bit's value is "1", its value is retained until a "0" is written to it.
TF
Write
Read
Function
bit 7
128
TEST
CSEL1
TSEL1
TSEL0
(bit 1)
(bit 0)
0
0
0
1
1
0
"Second" update
1
1
"Minute" update
Address C
Timer Counter 1
bit 5
bit 4
bit 3
bit 2
2048
1024
Data
0
Stops fixed-cycle timer interrupt function.
Starts fixed-cycle timer interrupt function.
1
The countdown that starts when the TE bit value changes from "0" to "1" always begins from the
preset value.
Data
The TF bit is cleared to zero to prepare for the next status detection
0
∗ Clearing this bit to zero does not enable the /INT low output status to be cleared (to Hi-Z).
1
This bit is invalid after a "1" has been written to it.
0
Fixed-cycle timer interrupt events are not detected.
Fixed-cycle timer interrupt events are detected.
1
(Result is retained until this bit is cleared to zero.)
bit 6
bit 5
bit 4
64
32
16
TE
WADA
USEL
TF
UF
TIE
CSEL0
UIE
Source clock
4096 Hz
/Once per 244.14 μ s
64 Hz
/
15.625
Once per
ms
/Once per second
/Once per minute
bit 1
bit 0
bit 7
bit 6
512
256
128
64
Description
Description
Page - 15
bit 3
bit 2
bit 1
8
4
2
2048
1024
512
TSEL1
FSEL1
FSEL0
AF
VLF
AIE
Auto reset time
Effects of
tRTN
RESET bits
122 μs
7.8125 ms
Does not operate
7.8125 ms
when the RESET
bit value is "1".
7.8125 ms
Address B
Timer Counter 0
bit 5
bit 4
bit 3
bit 2
bit 1
32
16
8
4
ETM26E-03
bit 0
1
256
TSEL0
VDET
RESET
bit 0
2
1