Fixed-Cycle Timer Interrupt Function; Diagram Of Fixed-Cycle Timer Interrupt Function - Epson RX-8801SA/JE Applications Manual

Real time clock module
Table of Contents

Advertisement

RX − 8801 SA / JE

8.3. Fixed-cycle Timer Interrupt Function

The fixed-cycle timer interrupt generation function generates an interrupt event periodically at any fixed cycle set
between 244.14 μs and 4095 minutes.
When an interrupt event is generated, the /INT pin goes to low level and "1" is set to the TF bit to report that an
event has occurred. (However, when a fixed-cycle timer interrupt event has been generated low-level output from
the /INT pin occurs only when the value of the control register's TIE bit is "1". Up to 7.8 ms after the interrupt
occurs, the /INT status is automatically cleared (/INT status changes from low-level to Hi-Z).
Example of
/INT operation
TIE = " 1 "
TE = " 0 " → " 1 "

8.3.1. Diagram of fixed-cycle timer interrupt function

Fixed-cycle timer starts
(1)
TE bit
TIE bit
/INT output
TF bit
Event occurs
(1)
∗ When the TE bit value changes from "0" to "1" the fixed-cycle timer function starts.
The counter always starts counting down from the preset value when the TE value changes from "0" to "1".
RTC internal operation
Write operation
(1) When a "1" is written to the TE bit, the fixed-cycle timer countdown starts from the preset value.
(2) A fixed-cycle timer interrupt event starts a countdown based on the countdown period (source clock). When the
count value changes from 001h to 000h, an interrupt event occurs.
∗ After the interrupt event that occurs when the count value changes from 001h to 000h, the counter
automatically reloads the preset value and again starts to count down. (Repeated operation)
(3) When a fixed-cycle timer interrupt event occurs, "1" is written to the TF bit.
(4) When the TF bit = "1" its value is retained until it is cleared to zero.
(5) If the TIE bit = "1" when a fixed-cycle timer interrupt occurs, /INT pin output goes low.
∗ If the TIE bit = "0" when a fixed-cycle timer interrupt occurs, /INT pin output remains Hi-Z.
(6) Output from the /INT pin remains low during the tRTN period following each event, after which it is automatically
cleared to Hi-Z status.
∗ /INT is again set low when the next interrupt event occurs.
(7) When a "0" is written to the TE bit, the fixed-cycle timer function is stopped and the /INT pin is set to Hi-Z status.
∗ When /INT = low, the fixed-cycle timer function is stopped. The tRTN period is the maximum amount of time
before the /INT pin status changes from low to Hi-Z.
(8) As long as /INT = low, the /INT pin status does not change when the TF bit value changes from "1" to "0".
(9) When /INT = low, the /INT pin status changes from low to Hi-Z as soon as the TIE bit value changes from "1" to
"0".
7.8ms
(Max.)
period
Operation of fixed-cycle timer
" 1 "
(5)
(6)
tRTN
(4)
(3)
period
period
(2)
001 h → 000 h
• • •
Page - 14
TIE = " 1 " → " 0 "
(9)
tRTN
tRTN
(8)
∗ Even when the TF
bit is cleared to zero,
the /INT status does
not change.
period
period
Fixed-cycle timer stops
(7)
(7)
∗ Even when the TE bit is
tRTN
cleared to zero, /INT
remains low during the
tRTN time.
(7)
ETM26E-03
" 1 "
" 0 "
" 1 "
" 0 "
Hi - z
" L "
" 1 "
" 0 "