6.13 Replacing presser foot
Removal
(1) Loosen the screw ① , and pull out the lap former
② toward you.
Fig. 6-40
(2) Loosen the screw ⑤ of the lifter lever stop ④ of
the presser lifter lever ③ .
④
Fig. 6-41
(3) Loosen the screw ⑥ , and while raising the upper
knife holder guide collar ⑦ slightly, pull until the
tip of the upper knife ⑧ separates from the presser
foot.
1 ㎜
⑧
Fig. 6-42
②
①
③
⑤
⑦
⑥
(4) Loosen the presser spring regulator ⑨ .
⑨
Fig. 6-43
(5) Remove the presser foot guide (left) ⑩ .
⑩
Fig. 6-44
Just loosen the screw ⑪ and leave it in the sew-
i
ing machine.
(6) Loosen the screw ⑬ of the presser foot ⑫ .
⑬
Fig. 6-45
41
6. Adjustments
⑪
⑫
VFK2560-8