6.9 Back-and-forth position of needle and looper
Adjust so that the looper ① tip makes 0 - 0.05 ㎜ contact
with the needle ② when the looper ① is moved from the
far right to the left and its tip meets to the center of the
right needle.
This adjustment is done after loosening the screw ③ .
0 - 0.05 ㎜
②
Fig. 6-23
Fig. 6-24
35
6. Adjustments
①
①
②
③
VFK2560-8