Firmware and Device Driver Error
Messages
This appendix contains error messages that may be generated by the socal and sf
device drivers and firmware of the Sun StorEdge A5000 disk array. Some of these
error messages are the same as those generated by the SPARCstorage™ Array.
This appendix does not include error messages generated by Solstice DiskSuite
software.
D.1

Target Numbers

The target number is the hexadecimal value for the physical target of the device that
has an error. For instance, in the following error message, the target number is 33:
Jan 15 14:59:05 macs1 unix: sf1:
ELS 0x52 to target 0x33 timed out
To determine the errant device:
1. Convert the hexadecimal value to binary.
In this case, 33 hexadecimal converts to 00110011 binary.
D-1