Limit Stop Reached Notification; Preset Designation; Pan/Tilt Position Feedback; Pan/Tilt Speed Feedback - Will Burt PositionIt PI-75 Operator's Manual

Rackmount controller
Hide thumbs Also See for PositionIt PI-75:
Table of Contents

Advertisement

3.9.2 Limit Stop Reached Notification

The Limit Stop Reached Notification notifies the user when either a programmable electronic
limit stop or a factory set limit stop has been reached. An arrow indicator icon will appear next to
"LIMSTOP" on the LCD display which signifies which Limit Stop has been reached:
Note: The Limit Stop Reached notification is not available on all Will-Burt positioner products.

3.9.3 Preset Designation

A [Preset: XX] appears on the Home Screen when 'go to' a preset command is sent to the
positioner ("XX" represent the specified preset number). When a 'go to' preset command is sent
to the positioner the preset text on the LCD Display will blink to signify the user that the
positioner is travelling to the preset location. When the positioner reaches its preset location the
text will stop blinking and turn solid. The preset location will remain on the LCD Display until the
positioner is moved away from the preset location.

3.9.4 Pan/Tilt Position Feedback

Pan and Tilt Position Feedback denotes the positioners current location. The default units for
positional feedback is degrees however this can be switched to radians within the Selector
Menu (See Section 3.10.2). The Position Feedback reads the absolute position of the positioner
relative to its home position. The user can zero the pan and tilt positional feedback in order to
'set' a specified 'zero' position (See Section 3.10.3).
Note: Pan/Tilt Position Feedback is available on most, but not all, Will-Burt positioner products.

3.9.5 Pan/Tilt Speed Feedback

Pan and Tilt Speed Feedback denotes the speed at which the positioner is travelling. Speed is
displayed as a value from 0-100 and is a percentage of the positioners maximum speed. A
specified maximum speed can be set in the Selector Menu (See Section 3.10.6).
PM-01005-REV 2
May 2021
-
Up Limit Stop Reached
-
Down Limit Stop Reached
-
Right (CW) Limit Stop Reached
-
Left (CCW) Limit Stop Reached
Original Instructions
R
C
ACKMOUNT
ONTROLLER
3-7