Summary of Contents for VWR avantor IL 56PR Premium
Page 1
Instruction manual ® INCU-Line Premium Peltier Cooled Incubators EU cat. no IL 56PR Premium 390-1351 IL 112PR Premium 390-1352 IL 240PR Premium 390-1353 Version 4.3 Issue 20/01/2022...
Page 2
Instruction Manual INCU-Line Premium Peltier Cooled Legal address of Manufacturer Europe VWR International bv Researchpark Haasrode 2020 Geldenaaksebaan 464 B-3001 Leuven +3216385011 be.vwr.com UK Importer VWR International Ltd Hunter Boulevard, Magna Park Lutterworth, Leicestershire, LE17 4XN uk.vwr.com Country of Origin...
Instruction Manual INCU-Line Premium Peltier Cooled Contents 1. IMPORTANT INFORMATION FOR THE USER ....................5 2. PACKAGE CONTENTS ............................ 6 3. BEFORE THE FIRST USE ..........................6 3.1. Shelf installation ................................7 3.2. Condensation in the chamber ............................8 3.3. Placement of samples ..............................8 3.4.
Page 4
Instruction Manual INCU-Line Premium Peltier Cooled 5.14. Types of accounts and their limits ..........................34 5.15. Interface ................................35 5.16. Time ................................36 5.17. Alarms ................................37 5.18. Network ................................38 5.19. Mail reports ..............................40 5.20. Corrections ..............................42 6.
Instruction Manual INCU-Line Premium Peltier Cooled 1. IMPORTANT INFORMATION FOR THE USER To guarantee your security and the longevity of the unit, please comply with the following rules: The unit cannot be installed: • outside, • in damp places or places which can be easily flooded, •...
Instruction Manual INCU-Line Premium Peltier Cooled 2. PACKAGE CONTENTS INCU-Line devices are delivered with the following equipment: INCU-Line IL 56PR Premium, 2 stainless steel wire shelves with set of slides – 2 pcs each, keys to the lock (2 pcs), Manufacturer test certificate at 37 C, Ethernet cable.
Instruction Manual INCU-Line Premium Peltier Cooled • Kept away from any heat sources • Not designed to be built-in e.g. within a wall cavity • Placed near a mains socket 230V/50Hz. Non-compliance with the above recommendations may result in damage to the unit or impair tech- nical parameters.
Instruction Manual INCU-Line Premium Peltier Cooled 1. Install the shelf bracket at the selected height by inserting it into appropriate slots on the chamber wall. 2. Install the second shelf bracket on the opposite chamber wall. 3. Slide the shelf into the shelf brackets. 4.
Instruction Manual INCU-Line Premium Peltier Cooled The picture below is an example of the placement of samples in the chamber. Front view Shelf Hmax = 2/3H Top view u+v+w > 1/3 a x+y+z > 1/3 b ≅ ≅ u v w ≅...
Instruction Manual INCU-Line Premium Peltier Cooled 4. DESCRIPTION OF THE UNIT (1) Electronic controller with 7” touch panel (2) USB port (3) Open door sensor (4) Internal LED light (5) Temperature sensor (6) Chamber fan (7) Key lock (8) Shelf (9) Internal glass door (10) Main power switch (11) Main power socket...
Instruction Manual INCU-Line Premium Peltier Cooled 5. UNIT OPERATION This symbol means that a given field / window can be moved in the direction shown in the picture. 5.1. Internal memory It may be necessary to use the data from the external memory – a USB stick. The USB stick should be for- matted the FAT 32 file system.
Instruction Manual INCU-Line Premium Peltier Cooled Figure 2 - Alphanumeric keypad Edition of field name Edition field Deleting the entire text Change to block letters (the size of letters is important when entering login and pass- word) Change to numbers or special characters Change to letters Deleting the entered character Confirmation of the entered text/closing the keypad...
Instruction Manual INCU-Line Premium Peltier Cooled Figure 3 - Login panel It is advised to set the password during the first run and make a note in a safe place in order to avoid inter- ference of unauthorized people. It is necessary to write down and remember the password because it is not possible to reset it! If the password has been lost, it is necessary to contact service.
Instruction Manual INCU-Line Premium Peltier Cooled Set temperature, » page to change, press the icon or value (for more information, see Elapsed or remaining time of program, to change, press the icon or val- » page ue (for more information, see Information panel –...
Instruction Manual INCU-Line Premium Peltier Cooled Figure 5 – Alarms panel If there are more alarms, a button appears on the right side of the list that allows you to expand on the entire screen. Figure 6 – Alarm details 5.5.3.
Instruction Manual INCU-Line Premium Peltier Cooled Internal light is switched on/off Closed door, open door. The number above the icon presents open door counter, press the icon to cancel the counter. The counter is also can- celled during turning on the device Icon for the fan.
Instruction Manual INCU-Line Premium Peltier Cooled time set Set time of performing segment time elapsed Elapsed time after reaching the segment time remaining Remaining time until the end of the segment 5.5.5. Status – protection and alarms In the left part there is information about the class and the upper and lower set values. It is associated with »page a running or completed program.
Instruction Manual INCU-Line Premium Peltier Cooled Figure 10 - List of programs Information about the number of created programs and the programs to be created is presented at the top 5.6.1. Program creating / edition Press the button , and a panel with program parameters will appear (Figure 11, Figure 12).
Instruction Manual INCU-Line Premium Peltier Cooled Figure 12 - Program parameters Cancels adding or editing of the program Switching to the edition of program segments With more parameters you can scroll the panel up and down 5.6.2. Segments edition Press the button , and the first program segment will appear (Figure 13, Figure 14, Figure 15).
Page 20
Instruction Manual INCU-Line Premium Peltier Cooled Figure 13 - Program segment edition Figure 14 - Program segment edition Figure 15- Program segment edition Page 20 / 54...
Instruction Manual INCU-Line Premium Peltier Cooled The navigation between: segments, program parameters and summary is done by swiping up the segment with the finger or touch the icon 5.6.3. Summary of segments In the summary in the figure all segments (Figure 16) are visible along with the entered settings: •...
Instruction Manual INCU-Line Premium Peltier Cooled 5.6.5. Priority Can be set in terms of: Parameters: The program without a ramp – the device starts the countdown of the segment time when the set tempera- ture is reached. The program with a ramp – first, the device counts down the time of the ramp and then proceeds to the seg- ment countdown when the set temperature is reached.
Instruction Manual INCU-Line Premium Peltier Cooled The temperature set in the segment cannot be higher than the upper protection temperature less 2°C, e.g. the upper protection temperature: 50°C the maximum temperature set in the segment that can be given is »...
Instruction Manual INCU-Line Premium Peltier Cooled The second way • In the main panel (Figure 20) press the icon in the upper right corner • Select the program you want to activate (Figure 21), you have got two additional options: Immediate start of the program Scheduled program start according to the set date and time Figure 20 - Main screen...
Instruction Manual INCU-Line Premium Peltier Cooled 5.8.1. Quick change the set temperature In order to quickly change the value of the set temperature of the program, press the icon in main screen (Figure The value of the temperature should be selected by scrolling the list up or down (Figure 22).
Instruction Manual INCU-Line Premium Peltier Cooled Figure 23 - Quick change of time 5.9. Statistics This panel displays statistics about the currently running program or program that has ended. Statistics are calculated separately for each segment and separately for each cycle. Data logging starts for calculation after 30 seconds from reaching the set temperature in the segment.
Instruction Manual INCU-Line Premium Peltier Cooled Figure 24 - Statistic 5.10. Data record Register window (Figure 26) contains the following information: • Time and date of the registered data [date], • Temperature value in °C measured by the main sensor inside the chamber [temp.], •...
Instruction Manual INCU-Line Premium Peltier Cooled Figure 26 - Data Register Data recording onto the USB flash drive. .csv files are available - semicolon sepa- rated by opening eg with a spreadsheet, .plkx - opening with the Premium Control application »...
Page 29
Instruction Manual INCU-Line Premium Peltier Cooled Figure 28 - Temperature graph Displays the entire graph / back to the list of graphs Back to Data Register The time of opening the graph depends on the number of saved da . The larger number of stored cells increases the opening time of the window.
Instruction Manual INCU-Line Premium Peltier Cooled 5.11. Event log The window displays information about registered events, alarms and errors. Data is only available for Super Admin users. Figure 30 – Event log Saving the data onto USB flash drive. .csv files are available - semicolon separated by opening e.g.
Instruction Manual INCU-Line Premium Peltier Cooled • Under Protection Stop – sub-temperature protection has been finished • Lower temp. alarm Start – lower temperature alarm has been activated • Lower temp. alarm End – lower temperature alarm has been finished •...
Instruction Manual INCU-Line Premium Peltier Cooled If an external storage is connected to the unit, then during the entry to the Info panel, the suggestion to save the unit configuration file on the USB stick appears (Figure 32). The file is used to create an offline program in the Premium Control application.
Instruction Manual INCU-Line Premium Peltier Cooled At the top there is information about: • User: the number of created users/ the total number of users to create • Available programs: the total number of available programs to be assigned to users 5.13.1.
Instruction Manual INCU-Line Premium Peltier Cooled 5.14. Types of accounts and their limits There are two different account types available. Each has its own qualities and limits described below. Admin account It has access to program management menu, where users can create or edit programs (programs), check their statistics (statistics and data register) and information about the system (info).
Instruction Manual INCU-Line Premium Peltier Cooled Figure 37 - Main menu - Super Admin Figure 38 - Main menu - Super Admin Information about which window is active indicates 5.15. Interface In this panel (Figure 39) you can: Change the language of device Set the time after which the screen will be dimmed Turn on/off the sound, alarm sounds will be still emitted Set the time after which the user will be automatically logged-out...
Instruction Manual INCU-Line Premium Peltier Cooled Figure 39 - Interface settings Confirms and saves changes Cancels the entered changes 5.16. Time In this panel you can: • change date / system time, • change time zone To change the system date or time, make changes and press the button (Figure 40).
Instruction Manual INCU-Line Premium Peltier Cooled Figure 40 - Time settings Confirms and saves changes Cancels the entered changes The same time zones are required for correct operation of programs on the device and com- puter. 5.17. Alarms You can set parameters related to alarms. •...
Instruction Manual INCU-Line Premium Peltier Cooled Figure 41 - Alarm settings Confirms and saves changes Cancels the entered changes In the field "lower alarm temp" you can set a value of -1°C to - 5°C and in the field "upper alarm temp"...
Page 39
Instruction Manual INCU-Line Premium Peltier Cooled Icon indicates the connection status. Device connect Device disconnect Figure 42 - LAN settings Confirms and saves changes Cancels the entered changes WiFi settings (Figure 43) • – press to refresh network list, • SSID –...
Instruction Manual INCU-Line Premium Peltier Cooled Figure 43 – WiFi settings Confirms and saves changes Cancels the entered changes 5.19. Mail reports In this window, you can set the parameters needed to activate notifications via e-mail. The panel is divided into three windows: Selection of event types for which notifications should be sent: (Figure 44) •...
Page 41
Instruction Manual INCU-Line Premium Peltier Cooled Confirms and saves changes Cancels the entered changes If you do not enable the "activate" option at the top of the panel, emails will not be sent! Sender and recipients (Figure 45) • Sender – sender’s e-mail address •...
Instruction Manual INCU-Line Premium Peltier Cooled You can also select the way of encryption TLS or SSL. The above information can be obtained from the email account provider. Figure 46 - E-mail – configuration of the sender e-mail account Connecting test Confirms and saves changes Cancels the entered changes Before testing the connection, make sure that the device is connected to a computer net-...
Page 43
Instruction Manual INCU-Line Premium Peltier Cooled The unit has been calibrated by the manufacturer in accordance with applicable norms. The temperature shown on the display corresponds with a great accuracy to the temperature in the geometrical centre of the chamber. For the correct operation of the unit it is not necessary to use User’s calibration.
Instruction Manual INCU-Line Premium Peltier Cooled 6. COMPONENTS OF THE UNIT 6.1. Door lock All ILPR units have been equipped with a door lock located in the door handle. Two keys are attached on the backside of the device. 6.2. Access port Ø...
Instruction Manual INCU-Line Premium Peltier Cooled 6.3. Open door alarm All incubators have been equipped with an open door sensor. If you open the door, icon: appear on the display. If you leave the door open for more the selected delay door alarm time, an alarm will sound and the control bar will be red.
Instruction Manual INCU-Line Premium Peltier Cooled 6.5. USB port To transfer data from the unit’s memory to the USB memory stick, connect the memory stick to the USB slot on the device. Go to Setup → Data record, press the button Select file type *.csv, *.plk Press: Data is copied.
Instruction Manual INCU-Line Premium Peltier Cooled 7. TEMPERATURE PROTECTION Temperature protection is included as standard, if damage occurs to the temperature controller or the user changes the temperature settings outside of the upper and lower limits, temperature protection will activate. Protection class 3.3 is a standard.
Instruction Manual INCU-Line Premium Peltier Cooled 10. CLEANING AND MAINTENANCE OF THE UNIT Before cleaning the device, it needs to be disconnected from the electrical supply! Maintenance (cleaning of the housing and the chamber) should be carried out at least once a week (depending on the environmental conditions in the workplace).
• Complete technical service contact information • Access to VWR’s Online Catalogue, and information about accessories and related products • Additional product information and special offers Contact us for information or technical assistance contact your local VWR representative or visit www.vwr.com Page 49 / 54...
The unit is not heating Check if the door of the unit is closed properly Clean the gasket Check if the fan is turned on If not please contact VWR service Does the installation site meet the installation Adapt to the installation re-...
VWR International warrants that this product will be free from defects in material and workmanship for a pe- riod of two (2) years from date of delivery. If a defect is present, VWR will, at its option and cost, repair, re- place, or refund the purchase price of this product to the customer, provided it is returned during the warranty period.
Instruction Manual INCU-Line Premium Peltier Cooled 14. PRODUCT IDENTIFICATION LABEL The product identification label is located on the left upper corner of the unit. An example of the rating plate. 1. Logo 2. Type of the unit 3. Catalogue number 4.
Instruction Manual INCU-Line Premium Peltier Cooled 15. TECHNICAL DATA IL 56PR PREMIUM IL 112PR PREMIUM IL 240PR PREMIUM Air convection forced Chamber capacity [l] Door type double (external solid, internal glass) Temperature range [ºC] 0…+70 (max 20 C below ambient temp.) Temperature resolution [ºC] every 0,1 microprocessor with a large 7“...
Page 54
18 Gul Drive Shanghai, 201203- China Northwest Business Park Singapore 629468 Tel.: 400 821 8006 Ballycoolin Tel: +65 6505 0760 Email: info_ china@ vwr.com Dublin 15 Email: sales.sg@ vwr.com Tel.: +353 01 88 22 222 Czech Republic Spain Email sales.ie@ vwr.com VW R International s.
Need help?
Do you have a question about the avantor IL 56PR Premium and is the answer not in the manual?
Questions and answers