Advertisement

Quick Links

Instruction manual
®
VWR
INCU-Line Premium Peltier Cooled Incubators
EU cat. no
IL 56PR Premium 390-1351
IL 112PR Premium 390-1352
IL 240PR Premium 390-1353
Version 4.3 Issue
20/01/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the avantor IL 56PR Premium and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VWR avantor IL 56PR Premium

  • Page 1 Instruction manual ® INCU-Line Premium Peltier Cooled Incubators EU cat. no IL 56PR Premium 390-1351 IL 112PR Premium 390-1352 IL 240PR Premium 390-1353 Version 4.3 Issue 20/01/2022...
  • Page 2 Instruction Manual INCU-Line Premium Peltier Cooled Legal address of Manufacturer Europe VWR International bv Researchpark Haasrode 2020 Geldenaaksebaan 464 B-3001 Leuven +3216385011 be.vwr.com UK Importer VWR International Ltd Hunter Boulevard, Magna Park Lutterworth, Leicestershire, LE17 4XN uk.vwr.com Country of Origin...
  • Page 3: Table Of Contents

    Instruction Manual INCU-Line Premium Peltier Cooled Contents 1. IMPORTANT INFORMATION FOR THE USER ....................5 2. PACKAGE CONTENTS ............................ 6 3. BEFORE THE FIRST USE ..........................6 3.1. Shelf installation ................................7 3.2. Condensation in the chamber ............................8 3.3. Placement of samples ..............................8 3.4.
  • Page 4 Instruction Manual INCU-Line Premium Peltier Cooled 5.14. Types of accounts and their limits ..........................34 5.15. Interface ................................35 5.16. Time ................................36 5.17. Alarms ................................37 5.18. Network ................................38 5.19. Mail reports ..............................40 5.20. Corrections ..............................42 6.
  • Page 5: Important Information For The User

    Instruction Manual INCU-Line Premium Peltier Cooled 1. IMPORTANT INFORMATION FOR THE USER To guarantee your security and the longevity of the unit, please comply with the following rules: The unit cannot be installed: • outside, • in damp places or places which can be easily flooded, •...
  • Page 6: Package Contents

    Instruction Manual INCU-Line Premium Peltier Cooled 2. PACKAGE CONTENTS INCU-Line devices are delivered with the following equipment: INCU-Line IL 56PR Premium, 2 stainless steel wire shelves with set of slides – 2 pcs each, keys to the lock (2 pcs), Manufacturer test certificate at 37 C, Ethernet cable.
  • Page 7: Shelf Installation

    Instruction Manual INCU-Line Premium Peltier Cooled • Kept away from any heat sources • Not designed to be built-in e.g. within a wall cavity • Placed near a mains socket 230V/50Hz. Non-compliance with the above recommendations may result in damage to the unit or impair tech- nical parameters.
  • Page 8: Condensation In The Chamber

    Instruction Manual INCU-Line Premium Peltier Cooled 1. Install the shelf bracket at the selected height by inserting it into appropriate slots on the chamber wall. 2. Install the second shelf bracket on the opposite chamber wall. 3. Slide the shelf into the shelf brackets. 4.
  • Page 9: Closing The Chamber Door

    Instruction Manual INCU-Line Premium Peltier Cooled The picture below is an example of the placement of samples in the chamber. Front view Shelf Hmax = 2/3H Top view u+v+w > 1/3 a x+y+z > 1/3 b ≅ ≅ u v w ≅...
  • Page 10: Description Of The Unit

    Instruction Manual INCU-Line Premium Peltier Cooled 4. DESCRIPTION OF THE UNIT (1) Electronic controller with 7” touch panel (2) USB port (3) Open door sensor (4) Internal LED light (5) Temperature sensor (6) Chamber fan (7) Key lock (8) Shelf (9) Internal glass door (10) Main power switch (11) Main power socket...
  • Page 11: Unit Operation

    Instruction Manual INCU-Line Premium Peltier Cooled 5. UNIT OPERATION This symbol means that a given field / window can be moved in the direction shown in the picture. 5.1. Internal memory It may be necessary to use the data from the external memory – a USB stick. The USB stick should be for- matted the FAT 32 file system.
  • Page 12: User Logging In

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 2 - Alphanumeric keypad Edition of field name Edition field Deleting the entire text Change to block letters (the size of letters is important when entering login and pass- word) Change to numbers or special characters Change to letters Deleting the entered character Confirmation of the entered text/closing the keypad...
  • Page 13: Main Screen

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 3 - Login panel It is advised to set the password during the first run and make a note in a safe place in order to avoid inter- ference of unauthorized people. It is necessary to write down and remember the password because it is not possible to reset it! If the password has been lost, it is necessary to contact service.
  • Page 14: Alarm Bar

    Instruction Manual INCU-Line Premium Peltier Cooled Set temperature, » page to change, press the icon or value (for more information, see Elapsed or remaining time of program, to change, press the icon or val- » page ue (for more information, see Information panel –...
  • Page 15: Information Panel

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 5 – Alarms panel If there are more alarms, a button appears on the right side of the list that allows you to expand on the entire screen. Figure 6 – Alarm details 5.5.3.
  • Page 16: Status - Description

    Instruction Manual INCU-Line Premium Peltier Cooled Internal light is switched on/off Closed door, open door. The number above the icon presents open door counter, press the icon to cancel the counter. The counter is also can- celled during turning on the device Icon for the fan.
  • Page 17: Status - Protection And Alarms

    Instruction Manual INCU-Line Premium Peltier Cooled time set Set time of performing segment time elapsed Elapsed time after reaching the segment time remaining Remaining time until the end of the segment 5.5.5. Status – protection and alarms In the left part there is information about the class and the upper and lower set values. It is associated with »page a running or completed program.
  • Page 18: Program Creating / Edition

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 10 - List of programs Information about the number of created programs and the programs to be created is presented at the top 5.6.1. Program creating / edition Press the button , and a panel with program parameters will appear (Figure 11, Figure 12).
  • Page 19: Segments Edition

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 12 - Program parameters Cancels adding or editing of the program Switching to the edition of program segments With more parameters you can scroll the panel up and down 5.6.2. Segments edition Press the button , and the first program segment will appear (Figure 13, Figure 14, Figure 15).
  • Page 20 Instruction Manual INCU-Line Premium Peltier Cooled Figure 13 - Program segment edition Figure 14 - Program segment edition Figure 15- Program segment edition Page 20 / 54...
  • Page 21: Summary Of Segments

    Instruction Manual INCU-Line Premium Peltier Cooled The navigation between: segments, program parameters and summary is done by swiping up the segment with the finger or touch the icon 5.6.3. Summary of segments In the summary in the figure all segments (Figure 16) are visible along with the entered settings: •...
  • Page 22: Priority

    Instruction Manual INCU-Line Premium Peltier Cooled 5.6.5. Priority Can be set in terms of: Parameters: The program without a ramp – the device starts the countdown of the segment time when the set tempera- ture is reached. The program with a ramp – first, the device counts down the time of the ramp and then proceeds to the seg- ment countdown when the set temperature is reached.
  • Page 23: Starting The Program

    Instruction Manual INCU-Line Premium Peltier Cooled The temperature set in the segment cannot be higher than the upper protection temperature less 2°C, e.g. the upper protection temperature: 50°C the maximum temperature set in the segment that can be given is »...
  • Page 24: Quick Change Of Parameters

    Instruction Manual INCU-Line Premium Peltier Cooled The second way • In the main panel (Figure 20) press the icon in the upper right corner • Select the program you want to activate (Figure 21), you have got two additional options: Immediate start of the program Scheduled program start according to the set date and time Figure 20 - Main screen...
  • Page 25: Quick Change The Set Temperature

    Instruction Manual INCU-Line Premium Peltier Cooled 5.8.1. Quick change the set temperature In order to quickly change the value of the set temperature of the program, press the icon in main screen (Figure The value of the temperature should be selected by scrolling the list up or down (Figure 22).
  • Page 26: Statistics

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 23 - Quick change of time 5.9. Statistics This panel displays statistics about the currently running program or program that has ended. Statistics are calculated separately for each segment and separately for each cycle. Data logging starts for calculation after 30 seconds from reaching the set temperature in the segment.
  • Page 27: Data Record

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 24 - Statistic 5.10. Data record Register window (Figure 26) contains the following information: • Time and date of the registered data [date], • Temperature value in °C measured by the main sensor inside the chamber [temp.], •...
  • Page 28: Graph

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 26 - Data Register Data recording onto the USB flash drive. .csv files are available - semicolon sepa- rated by opening eg with a spreadsheet, .plkx - opening with the Premium Control application »...
  • Page 29 Instruction Manual INCU-Line Premium Peltier Cooled Figure 28 - Temperature graph Displays the entire graph / back to the list of graphs Back to Data Register The time of opening the graph depends on the number of saved da . The larger number of stored cells increases the opening time of the window.
  • Page 30: Event Log

    Instruction Manual INCU-Line Premium Peltier Cooled 5.11. Event log The window displays information about registered events, alarms and errors. Data is only available for Super Admin users. Figure 30 – Event log Saving the data onto USB flash drive. .csv files are available - semicolon separated by opening e.g.
  • Page 31: Info

    Instruction Manual INCU-Line Premium Peltier Cooled • Under Protection Stop – sub-temperature protection has been finished • Lower temp. alarm Start – lower temperature alarm has been activated • Lower temp. alarm End – lower temperature alarm has been finished •...
  • Page 32: Users

    Instruction Manual INCU-Line Premium Peltier Cooled If an external storage is connected to the unit, then during the entry to the Info panel, the suggestion to save the unit configuration file on the USB stick appears (Figure 32). The file is used to create an offline program in the Premium Control application.
  • Page 33: User Creating / Edition

    Instruction Manual INCU-Line Premium Peltier Cooled At the top there is information about: • User: the number of created users/ the total number of users to create • Available programs: the total number of available programs to be assigned to users 5.13.1.
  • Page 34: Types Of Accounts And Their Limits

    Instruction Manual INCU-Line Premium Peltier Cooled 5.14. Types of accounts and their limits There are two different account types available. Each has its own qualities and limits described below. Admin account It has access to program management menu, where users can create or edit programs (programs), check their statistics (statistics and data register) and information about the system (info).
  • Page 35: Interface

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 37 - Main menu - Super Admin Figure 38 - Main menu - Super Admin Information about which window is active indicates 5.15. Interface In this panel (Figure 39) you can: Change the language of device Set the time after which the screen will be dimmed Turn on/off the sound, alarm sounds will be still emitted Set the time after which the user will be automatically logged-out...
  • Page 36: Time

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 39 - Interface settings Confirms and saves changes Cancels the entered changes 5.16. Time In this panel you can: • change date / system time, • change time zone To change the system date or time, make changes and press the button (Figure 40).
  • Page 37: Alarms

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 40 - Time settings Confirms and saves changes Cancels the entered changes The same time zones are required for correct operation of programs on the device and com- puter. 5.17. Alarms You can set parameters related to alarms. •...
  • Page 38: Network

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 41 - Alarm settings Confirms and saves changes Cancels the entered changes In the field "lower alarm temp" you can set a value of -1°C to - 5°C and in the field "upper alarm temp"...
  • Page 39 Instruction Manual INCU-Line Premium Peltier Cooled Icon indicates the connection status. Device connect Device disconnect Figure 42 - LAN settings Confirms and saves changes Cancels the entered changes WiFi settings (Figure 43) • – press to refresh network list, • SSID –...
  • Page 40: Mail Reports

    Instruction Manual INCU-Line Premium Peltier Cooled Figure 43 – WiFi settings Confirms and saves changes Cancels the entered changes 5.19. Mail reports In this window, you can set the parameters needed to activate notifications via e-mail. The panel is divided into three windows: Selection of event types for which notifications should be sent: (Figure 44) •...
  • Page 41 Instruction Manual INCU-Line Premium Peltier Cooled Confirms and saves changes Cancels the entered changes If you do not enable the "activate" option at the top of the panel, emails will not be sent! Sender and recipients (Figure 45) • Sender – sender’s e-mail address •...
  • Page 42: Corrections

    Instruction Manual INCU-Line Premium Peltier Cooled You can also select the way of encryption TLS or SSL. The above information can be obtained from the email account provider. Figure 46 - E-mail – configuration of the sender e-mail account Connecting test Confirms and saves changes Cancels the entered changes Before testing the connection, make sure that the device is connected to a computer net-...
  • Page 43 Instruction Manual INCU-Line Premium Peltier Cooled The unit has been calibrated by the manufacturer in accordance with applicable norms. The temperature shown on the display corresponds with a great accuracy to the temperature in the geometrical centre of the chamber. For the correct operation of the unit it is not necessary to use User’s calibration.
  • Page 44: Components Of The Unit

    Instruction Manual INCU-Line Premium Peltier Cooled 6. COMPONENTS OF THE UNIT 6.1. Door lock All ILPR units have been equipped with a door lock located in the door handle. Two keys are attached on the backside of the device. 6.2. Access port Ø...
  • Page 45: Open Door Alarm

    Instruction Manual INCU-Line Premium Peltier Cooled 6.3. Open door alarm All incubators have been equipped with an open door sensor. If you open the door, icon: appear on the display. If you leave the door open for more the selected delay door alarm time, an alarm will sound and the control bar will be red.
  • Page 46: Usb Port

    Instruction Manual INCU-Line Premium Peltier Cooled 6.5. USB port To transfer data from the unit’s memory to the USB memory stick, connect the memory stick to the USB slot on the device. Go to Setup → Data record, press the button Select file type *.csv, *.plk Press: Data is copied.
  • Page 47: Temperature Protection

    Instruction Manual INCU-Line Premium Peltier Cooled 7. TEMPERATURE PROTECTION Temperature protection is included as standard, if damage occurs to the temperature controller or the user changes the temperature settings outside of the upper and lower limits, temperature protection will activate. Protection class 3.3 is a standard.
  • Page 48: Cleaning And Maintenance Of The Unit

    Instruction Manual INCU-Line Premium Peltier Cooled 10. CLEANING AND MAINTENANCE OF THE UNIT Before cleaning the device, it needs to be disconnected from the electrical supply! Maintenance (cleaning of the housing and the chamber) should be carried out at least once a week (depending on the environmental conditions in the workplace).
  • Page 49: Interior Cleaning

    • Complete technical service contact information • Access to VWR’s Online Catalogue, and information about accessories and related products • Additional product information and special offers Contact us for information or technical assistance contact your local VWR representative or visit www.vwr.com Page 49 / 54...
  • Page 50: Possible Defects

    The unit is not heating Check if the door of the unit is closed properly Clean the gasket Check if the fan is turned on If not please contact VWR service Does the installation site meet the installation Adapt to the installation re-...
  • Page 51: Warranty Conditions

    VWR International warrants that this product will be free from defects in material and workmanship for a pe- riod of two (2) years from date of delivery. If a defect is present, VWR will, at its option and cost, repair, re- place, or refund the purchase price of this product to the customer, provided it is returned during the warranty period.
  • Page 52: Product Identification Label

    Instruction Manual INCU-Line Premium Peltier Cooled 14. PRODUCT IDENTIFICATION LABEL The product identification label is located on the left upper corner of the unit. An example of the rating plate. 1. Logo 2. Type of the unit 3. Catalogue number 4.
  • Page 53: Technical Data

    Instruction Manual INCU-Line Premium Peltier Cooled 15. TECHNICAL DATA IL 56PR PREMIUM IL 112PR PREMIUM IL 240PR PREMIUM Air convection forced Chamber capacity [l] Door type double (external solid, internal glass) Temperature range [ºC] 0…+70 (max 20 C below ambient temp.) Temperature resolution [ºC] every 0,1 microprocessor with a large 7“...
  • Page 54 18 Gul Drive Shanghai, 201203- China Northwest Business Park Singapore 629468 Tel.: 400 821 8006 Ballycoolin Tel: +65 6505 0760 Email: info_ china@ vwr.com Dublin 15 Email: sales.sg@ vwr.com Tel.: +353 01 88 22 222 Czech Republic Spain Email sales.ie@ vwr.com VW R International s.