Gelectrical Data; Hoperating Conditions; Environmental Conditions; Electrical Power Supply - Graco 127642 Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

G
ELECTRICAL DATA
EN
PUMP MODEL
120V version
(*) Refers to functioning in by-pass mode.
H
OPERATING CONDITIONS
H.1
TEMPERATURE
RELATIVE
HUMIDITY
LIGHTING
NOTICE
H.2
NOTICE
NOTICE
H.3
NOTICE
NOTICE
H.4
FLUIDS
PERMITTED
FLUIDS NON-
PERMITTED AND
RELATED
HAZARDS
8
POWER SUPPLY
Current
Voltage (V)
AC
120

ENVIRONMENTAL CONDITIONS

min. +23 °F / max +104 °F
min. -5 °C / max +40 °C
max. 90%
The environment must conform to directive 89/654/EEC
on work environments.
In case of non-EU countries, refer to directive EN ISO
12100-2 § 4.8.6.
The temperature limits shown apply to the pump
components and must be respected to avoid possible
damage or malfunction.

ELECTRICAL POWER SUPPLY

The pump must be powered by AC single-phase line,
the nominal values of which are indicated on the ta-
ble in the paragraph "G - ELECTRICAL DATA".
The maximum acceptable variations from the electri-
cal parameters are:
Voltage:
+/- 5% of the nominal value
Frequency: +/- 2% of the nominal value
Power supply from lines with values that do not fall
within the indicated limits could cause damage to
the electrical components.

DUTY CYCLE

The pumps have been designed for intermittent use
and a 20-minute duty cycle under conditions of max-
imum back pressure.
Functioning under by-pass conditions is only
allowed for short periods of time (max. 3 minutes).

PERMITTED AND NON-PERMITTED FLUIDS

- DEF;
- WATER
- DIESEL FUEL
- GASOLINE
- INFLAMMABLE LIQUIDS
- CORROSIVE CHEMICAL PRODUCTS - CORROSION AND INJURY TO
- SOLVENTS
- LIQUIDS WITH VISCOSITY >20 cst
CURRENT
Frequency (Hz)
Max (*) (A)
60
3.5
- OXIDATION OF PUMP
- FIRE
- EXPLOSION
PERSONS
- DAMAGE TO GASKET SEALS
- MOTOR OVERLOAD
M0307

Advertisement

Table of Contents
loading

Table of Contents