Performance Charts - Graco Aluminum Husky 2150 LP Instructions Manual

Air-operated diaphragm pumps
Hide thumbs Also See for Aluminum Husky 2150 LP:
Table of Contents

Advertisement

Performance Charts

Performance Charts
Pressure Chart
120
(8.3, 0.83)
100
(6.9, 0.69)
80
(5.5, 0.55)
60
(4.1, 0.41)
40
(2.8, 0.28)
20
(1.4, 0.14)
0
0
20
(76)
(Pump tested in water with inlet submerged)
Flow Chart
180
150
(5.10
(10.3, 1.03)
150
125
(4.25)
(8.6, 0.86)
120
100
(3.40
(6.9, 0.69)
90
75
(2.55)
(5.2, 0.52)
60
50
(1.70)
(3.4, 0.34)
30
25
(0.85)
(1.7, 0.17)
0
0
20
(76)
(Pump tested in water with inlet submerged)
To find Fluid Outlet Pressure (psi/bar/MPa) at a
specific fluid flow (gpm/lpm) and operating air pressure
(psi/bar/MPa):
1. Locate fluid flow rate along bottom of chart.
2. Follow vertical line up to intersection with selected
operating air pressure curve.
3. Follow left to scale to read fluid outlet pressure.
30
D
C
B
A
40
60
80
100
(151)
(227)
(303)
(379)
FLUID FLOW gpm (lpm)
D
C
B
A
40
60
80
100
(151)
(227)
(303)
(379)
FLUID FLOW gpm (lpm)
120
140
160
(454)
(530)
(606)
120
140
160
(454)
(530)
(606)
To find Air Consumption (scfm or m
fluid flow (gpm/lpm) and air pressure (psi/bar/MPa):
1. Locate fluid flow rate along bottom of chart.
2. Read vertical line up to intersection with selected
operating air pressure curve.
3. Follow left to scale to read air consumption.
OPERATING AIR PRESSURE
A 40 psi air (2.8 bar, 0.28 MPa)
B 70 psi air (4.8 bar, 0.48 MPa)
C 100 psi air (7 bar, 0.7 MPa)
D 120 psi air (8.62 bar, 0.86 MPa)
OPERATING AIR PRESSURE
A 40 psi air (2.8 bar, 0.28 MPa)
B 70 psi air (4.8 bar, 0.48 MPa)
C 100 psi air (7 bar, 0.7 MPa)
D 120 psi air (8.62 bar, 0.86 MPa)
3
/min) at a specific
3A8693C

Advertisement

Table of Contents
loading

This manual is also suitable for:

3a8693c

Table of Contents