Model
Capacity (VA)
Capacity (Watts)
Input
Input Voltage Range
Frequency Range
Output
On Battery Output Voltage
On Battery Output Frequency
Transfer Time (Typical)
Overload Protection
Surge Protection and Filtering
Lightning / Surge Protection
Internet Ready (DSL / Phone /
FAX / Modem Protection)
Physical
Total # of UPS Receptacles
Maximum Dimensions
Weight
Battery
Sealed Maintenance Free Lead
Acid Battery
User Replaceable
Typical Recharge Time
Warning Diagnostics
Indicators
Audible Alarms
Environmental
Operating Temperature
Operating Relative Humidity
Communication
TM
PowerPanel
Software
Management
Self-Test
Auto-Charger
Auto-Restart
USB
TECHNICAL SPECIFICATIONS
Simulated Sine Wave at 120Vac +/- 5%
On Utility: Circuit Breaker, On Battery: Internal Current Limiting
Power On, Using Battery, Boost, Buck
Guaranteed Uninterruptible Power System
OP650
650VA
350W
85Vac – 145Vac
47 – 63 Hz
60 Hz +/- 1%
4ms
Yes
RJ11/RJ45 (One In/One Out)
3
28.3cm*9.1cm*16.4cm
6.4kg
12V / 7AHx1
Yes, Hot Swappable Battery Pack
8 Hours
On Battery, Low Battery, Overload
+32°F to 95°F ( 0°C to 35°C )
0 to 95% NON-CONDENSING
Windows 95/98/ME/NT/2000/XP
Yes
Yes
Yes
Yes
7
OP650