BATTERY REPLACEMENT PROCEDURE:
1. Turn off and unplug all connected equipment.
2. Turn the UPS off and unplug it from the AC power source.
3. Turn the UPS upside down.
4. Remove the 4 retaining screws and remove the cover.
5. Remove the battery from the compartment.
6. Disconnect the battery wires from the battery.
7. Install the replacement battery by connecting the red wire to the
positive (+) terminal of the battery and connecting the black
wire to the negative (-) terminal of the battery.
8. Slide the battery back into the compartment.
9. Replace the cover and the 4 retaining screws.
10. Recharge the unit for 4 – 8 hours to ensure the UPS performs
expected runtime
REMINDER: Batteries are consider HAZARDOUS WASTE and must be disposed of
properly. Contact your local government for more information about proper disposal and
recycling of batteries.
STORAGE:
First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all
cables connected to the UPS to avoid battery drain. To store your UPS for an extended
period, cover it and store with the battery fully charged. Recharge the battery every three
months to insure battery life. If the battery remains uncharged for an extended period of time,
it may suffer permanent loss of capacity.