6 Transport and storage

Check the analog amplifier for transport damage. If there are obvious signs of
damage, please inform the transport company and Bosch Rexroth immediately.
If the analog amplifier is dropped, continued use is not permissible because
unseen damage may affect its reliability.
6�1 Transporting and storing the analog amplifier
• Shock resistance:
Transport shock (IEC 60068-2-27) 3x in each direction (positive/negative) and
15 g / 11 ms in each axis.
• Store analog amplifiers at an average relative humidity of 60% and at
a temperature between -10°C and +30°C.
• After a storage time of more than 5 years, the analog amplifier must be checked
by the manufacturer before use.