Bosch Rexroth RA 10 Series Instruction Manual page 24

Analog amplifier
Table of Contents

Advertisement

24/48
Analog amplifier RA | Installation
Bosch Rexroth AG, RE 95230-B/2021-12-01
3� Cut the wires to length, crimp the contacts and insert them into the
contact carrier.
– As there is little space in the handle shell, the wires must not be too long.
Recommendation: Length of wires for contact 1 and 14 of insulation hose end
50 mm, for subsequent contact numbers in each case approx. 5 mm longer
(contacts 2 and 15 => 55 mm, contact 3 and 16 => 60 mm, etc.). The last
wires of contacts 13 and 25 should not be longer than 12 cm.
Casting for screw
Fig� 12: Cutting wires to length
– The contact carrier is positioned correctly if contacts 1 and 14 are on the
side of the cable entry opening of the handle shell.
– We recommend starting the cutting to length, crimping and plugging from
the cable entry side (either on one side with contact 1 to 13, then 14 to 25,
or alternately, contact 1, 14, 2, 15, etc.).
– The wires must lead away from the crimping contacts in a light bend.
50 mm
Contact 1 or 14