7� Completely insert the contact carrier into the handle shell.
– No strong force may be required, otherwise wires or contacts may be damaged;
the correct wire length and/or the wire routing (only small bend over the
contacts; no twisting of the wires between each other) must be checked.
– Ensure that the (optional) resistor is correctly seated.
Position of resistor
Fig� 19: Position, resistor
8� Equip the screw for the contact carrier with the flat seal ring.
9� Screw the contact carrier to the handle shell using the screw
(and flat seal ring!).
– Tightening torque 0.4 – 0.7 Nm
Fig� 20: Assembling the connector
10� Insert the seal for the contact carrier.
– The seal must be inserted with the concave side to the contact carrier
(inside) (straight surface must be visible from the outside).
– The seal must fully lie between handle shell and contact carrier.