Information On Wiring And Circuitry - Bosch Rexroth RA 10 Series Instruction Manual

Analog amplifier
Table of Contents

Advertisement

Connection variant 11
Potentiometer via switch
approx.
USETPOINT
5.1 kΩ
U Batt
Fig� 33: Connection variant 11
Monitoring of cable break is not possible with this variant.
7�5�4 Information on wiring and circuitry
• Connections to systems with a different electrical ground or power source
require galvanic isolation.
• The product may only be wired when it is de-energized.
• Lines to the electronics must not be routed close to other power-conducting lines
in the device or vehicle.
• The wiring harness should be mechanically fixed in the area in which the analog
amplifier is installed. The wiring harness must be mounted in such a way that an
in-phase excitation with the analog amplifier occurs (e.g. at the analog amplifier
fixing point).
• If possible, lines are to be routed inside the vehicle. If the lines are routed
outside the vehicle, make sure that they are securely mounted.
• Lines must not be kinked or twisted, must not rub against edges and must not be
routed through sharp-edged ducts without protection.
• Lines are to be routed with sufficient distance to hot or moving vehicle parts.
• PWM outputs must not be connected to one another or bridged.
• The outputs must not be used to operate incandescent lamps due to the inrush
current properties of these loads. Exceptions are permissible for signal lamps
with low power if it is ensured that the inrush current does not exceed the limit
values of the data sheet 95230.
• The power outputs are not suitable for the operation of LEDs.
• The outputs may not be externally connected to battery.
• Proportional solenoids which are operated in a current-controlled way must not
be connected to spark-suppression diodes.
Installation | Analog amplifier RA
8.4V
Channel 1
Setpoint
Output stage
processing
4.0V
Solenoid 1
8.4V
Channel 2
Output stage
Setpoint
processing
4.0V
Solenoid 2
9
Parallel operation
RE 95230-B/2021-12-01, Bosch Rexroth AG
39/48
10.0V
USETPOINT
10.0V
USETPOINT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth ra2-1/10

Table of Contents