ClimaCon F
Technical description

3.2.2 ClimaCon F 210, F 310

1
Fig. 3:
Design F 210, F 310
1
Control unit
2
Base plate
3
Terminal strip
4
Opening for the cable feed
5
Release clip
3.3

Functional description

The ClimaCon F room thermostats are used to control the
temperature of surface heating and cooling systems as
well as heating and cooling ceilings in detached houses
and multiple dwellings.
The ClimaCon F room thermostats control electrothermal
actuators (e.g. Aktor T 2P) via a cable connection.
Valves are opened or closed via the electrothermal
actuators. If the room temperature is lower than the
setpoint temperature, the valves are opened; if the room
temperature reaches the setpoint temperature, the valves
are closed.
The setpoint temperature is adjusted at the room
thermostat .
All product variants offer the same basic functions.
3.3.1

App connection (F 210, F 310)

The ClimaCon F 210 and F 310 product variants can be
programmed via smartphone app.
Three modes are available for temperature control.
3.3.1.1 Auto mode
In Auto mode, the temperature control follows a time
profile (see par. 7.2.3.2 on page 18).
8
2
3
5
4
3.3.1.2 Eco mode
In Eco mode, the temperature is constantly regulated to
the "Eco setback temperature" (see par. 7.2.3.1 on page
18).
ClimaCon F 210, F 310 devices are equipped with a
setback output (master). Whenever the Eco mode is
active, a voltage is present at this output. The setback
output can be connected to the setback input (slave) of a
ClimaCon F 90, F 100 room thermostat. The voltage at the
setback input reduces the temperature at the slave room
thermostat by 4 Kelvin compared to the temperature set
2
at the scale (position
in Fig. 4 on page 9).
3.3.1.3 Manual mode
You always have the option to set the temperature
manually (see par. 8.2.3 on page 21).

3.3.2 Functions in detail

3.3.2.1 ClimaCon F 90 - Only heating / only cooling
Rotary wheel for adjusting the setpoint temperature
Frost protection can be activated via rotary wheel
Slave input for connection to a master room
thermostat
3.3.2.2 ClimaCon F 100 - Heating or Cooling
Rotary wheel for adjusting the setpoint temperature
Frost protection can be activated via rotary wheel
Slave input for connection to master room thermostat
Switching between heating and cooling via change-
over signal
3.3.2.3 ClimaCon F 210 - Only heating / only cooling
Dot-Matrix display for visualisation of the setpoint
temperature, the actual temperature, various error
codes, the display "BLu" for the teach-in mode, as well
as the OFF display when the device is switched off
LED display heating or cooling
LED display with touch surfaces for adjusting the
setpoint temperature via the Plus and Minus keys and
for switching between Auto and Eco mode
Control via app (Bluetooth)
Possible modes: Auto (daily or weekly schedule), Eco/
Setback, Manual
Frost protection (6 °C/ 43 °F) is activated when the
room thermostat is switched off
Temperature limitation and offset temperature
adjustable
Master output for controlling the setback temperature
of a slave room thermostat
115500983-V02.01.2022