Power Connections; Retightening The Power Connections; Fan Replacement; Brake Chopper Module Cubicle - ABB ACS880-607LC Hardware Manual

3-phase dynamic brake units
Hide thumbs Also See for ACS880-607LC:
Table of Contents

Advertisement

68 Maintenance

Power connections

Retightening the power connections

WARNING!
Obey the safety instructions given in ACS880 liquid-cooled multidrive
cabinets and modules safety instructions (3AXD50000048633 [English]).
If you ignore the safety instructions, injury or death, or damage to the
equipment can occur.
If you are not a qualified electrical professional, do not do installation or
maintenance work.
1. Stop the drive and do the steps in section
you start the work.
2. Examine the tightness of the cable connections. Use the tightening torques given in the
technical data.

Fan replacement

Brake chopper module cubicle

WARNING!
Obey the safety instructions of the drive. If you ignore them, injury or death,
or damage to the equipment can occur. If you are not a qualified electrical
professional, do not do installation or maintenance work.
WARNING!
Use the required personal protective equipment. Wear protective gloves and long
sleeves. Some parts have sharp edges.
1. Repeat the steps described in section
2. Remove any shrouding in front of the cooling fan.
3. Disconnect the fan wiring.
4. Undo the two retaining screws (a).
5. Pull the fan outwards to separate it from the heat exchanger housing.
6. Install new fan in reverse order. Align the guide pins (b) at the rear of the fan cowling
with the slots (c) in the module bottom guide, then reinstall the retaining screws (a).
Electrical safety precautions (page 35)
Electrical safety precautions (page
before
35).

Advertisement

Table of Contents
loading

Table of Contents