Maintenance - STIEBEL ELTRON DHE Connect 18 Operation And Installation Manual

Fully electronically controlled comfort instantaneous water heater with mini wireless remote control
Hide thumbs Also See for DHE Connect 18:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 65
INSTALLATION

Maintenance

17. Maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
This appliance contains capacitors which are discharged
when disconnected from the power supply. The capacitor
discharge voltage may briefly exceed 60 V DC.
Draining the appliance
The appliance can be drained for maintenance work.
WARNING Burns
Hot water may escape when you drain the appliance.
f Close the 3-way ball shut-off valve or the shut-off valve in the
f
cold water inlet line.
f Open all draw-off valves.
f
f Undo the water connections on the appliance.
f
f Store the dismantled appliance in a room free from the risk
f
of frost, as water residues remaining inside the appliance can
freeze and cause damage.
114
|DHE Connect | DHE Touch   
Cleaning the strainer
If dirty, clean the strainer in the threaded cold water fitting. Close
the 3-way ball shut-off valve or the shut-off valve in the cold water
inlet line before removing, cleaning and refitting the strainer.
www.stiebel-eltron.com

Advertisement

Table of Contents
loading

Table of Contents