STIEBEL ELTRON DHC 3-1 Operation And Installation
STIEBEL ELTRON DHC 3-1 Operation And Installation

STIEBEL ELTRON DHC 3-1 Operation And Installation

Tankless electric water heater

Advertisement

OperatiOn and installatiOn
UtilisatiOn et installatiOn
Operación e instalación
tanKless electric Water Heater | cHaUFFe-eaU ÉlectriQUe sans accUMUlateUr |
calentadOr de aGUa instantaneOs sin tanQUe
» dHc 3-1
» dHc 3-2
» dHc 4-2
» dHc 4-3
» dHc 5-2
» dHc 6-2
» dHc 8-2
» dHc 9-3
» dHc 10-2
The DHC series is tested and
certified by WQA against
NSF/ANSI 372 for "lead
free" compliance.
Flow Factor ~ 216-765-4231
www.flowfactor.com

Advertisement

Table of Contents
loading

Summary of Contents for STIEBEL ELTRON DHC 3-1

  • Page 1 OperatiOn and installatiOn UtilisatiOn et installatiOn Operación e instalación tanKless electric Water Heater | cHaUFFe-eaU ÉlectriQUe sans accUMUlateUr | calentadOr de aGUa instantaneOs sin tanQUe » dHc 3-1 » dHc 3-2 » dHc 4-2 » dHc 4-3 » dHc 5-2 »...
  • Page 2: Table Of Contents

    Flow Factor ~ 216-765-4231 Contents | operation safety information OperatiOn General information �����������������������������������������2 1.1.1 structure of safety information Safety information ����������������������������������������������� 2 Other symbols in this document ������������������������������ 2 Safety ����������������������������������������������������������2 KEYWORD Type of risk Intended use ������������������������������������������������������ 3 Here, possible consequences are listed that may General Information���������������������������������������������...
  • Page 3: Operation

    Flow Factor ~ 216-765-4231 operation General intended use DANGER Burns Water temperatures over 125 °F (52 °C)can cause severe The appliance is intended for heating domestic hot water and can burns instantly or death from scalding. supply one draw-off point. Any other use beyond that described shall be deemed inappro- WARNING Injury priate.
  • Page 4: Mounting The Unit

    Flow Factor ~ 216-765-4231 installation mountinG tHe unit installation 5. Mount unit securely to wall by putting two screws through mounting holes. Screws and plastic wall anchors for mounting on masonry or wood are provided. mounting the unit 1 Electrical junction box 2 Water supply line for faucet installation 3 3/8“...
  • Page 5: Electrical Connection

    The „live“ wires must be connected to the slots on the use. The unit itself does not require any regular maintenance. terminal block marked N and L (DHC 3-1 only) or L and L (all However, to ensure consistent water flow, it is recommended other versions).
  • Page 6: Technical Data

    DHC 6-2, DHC 8-2, DHC 10-2 2/GRD ~ 208 / 240 V electrical supply cable DHC 9-3 cold water connection " NPT 2/GRD ~ 277 V hot water connection " NPT DHC 3-1 1/N/GRD ~ 120 V www.flowfactor.com | DHC www.stiebel-eltron.Com...
  • Page 7: Data Table

    Flow Factor ~ 216-765-4231 installation temperature inCrease above ambient water temperature data table model DHC 3-1 DHC 3-2 DHC 4-2 DHC 4-3 DHC 5-2 DHC 6-2 DHC 8-2 DHC 9-3 DHC 10-2 074050 074052 074053 074051 074054 074424 074055 232204...
  • Page 8: Troubleshooting

    STIEBEL ELTRON is happy to provide technical assistance. In most instances, we can resolve the problem over the phone. Open flow adjustment screw Filter screen reset button from safety thermal cut out 12. spare parts no. spare part DHC 3-1 DHC 3-2 DHC 4-2 DHC 4-3 DHC 5-2 DHC 6-2...
  • Page 9: Environment And Recycling

    apply to appliances acquired outside of Germany. In countries where our subsidiaries sell our products, it is increasingly the Flow Factor ~ 216-765-4231 case that warranties can only be issued by those subsidiaries. Such warranties are only granted if the subsidiary has issued INSTALLATION INSTALLATION | ENVIRONMENT AND RECYCLING| WARRANTY its own terms of warranty.

Table of Contents