4 Before installation
Fig.12
3 LW boilers
1
2
1 System water supply; connection DN 65/DIN 2631 (4
holes)
2 System return; connection DN 65/DIN 2631 (4 holes)
3 Gas supply connection DN 65/DIN 2633 (4 holes)
4 Suspension points
Air supply 150 mm
Flue gas outlet 150 mm
14
MCA
4.3.2
Sample configuration drawing with 3 LW boilers; 2 x MCA 160
and 1 x MCA 45-115.
500
325
1805
80
600
C
630
630
1890

Linear, wall-mounted - LW

305
173
30
226
3
630
325
A System flow centre line = 330 mm up to 350 kW and
560 mm above 350 kW
B System return centre line = 210 mm to 350 kW and
200 mm above 350 kW
C Low-loss header; DN 65 connection with adapter to
DIN 100 = 361 mm to 350 kW and 701 mm above
350 kW
4
4
125
7680446 - v.01 - 14082017
AD-4100020-01