RCm RG900 Installation Manual page 22

For agco rogator c-series
Table of Contents

Advertisement

CHAPTER 3
4. Remove the bolts securing the Product Controller ECU to the mounting plate.
5. Disconnect the electrical connectors from the ECU by loosening the 1/ 4" hex screw of each connector, and set
the ECU aside. The RCM - Sprayer will replace this device.
6. Reinstall the ECU mounting plate into the rear of the ECU cabinet using the original hardware.
7. Locate the X0778 connectors (RVN PWR) and X0780 (RVN SIGNALS) as shown in Figure 8, "Power and Signal
Connections," and disconnect the ISO Product Controller Node jumper cable connections. The jumper cable
may be removed with the ISO Product Controller ECU.
FIGURE 8. Power and Signal Connections
8. For signals to reach the X0780 connector, complete step a through step e.
a.
Locate the RCM - Sprayer bulkhead cable (P/ N 115-2005- 018) and connect the black 6- pin Deutsch plug
into the mating connector labeled "Raven Node Power" in the ECU cabinet.
b.
Connect the gray 12-pin Deutsch plug to the mating connector labeled "Raven Node Signals" in the ECU
cabinet.
c.
Remove the cap from the X0777 (RAVEN SIGNAL NODE).
d.
Connect the X0775 (CNTRL SIGNAL) to X0777 (RAVEN NODE SIGNAL).
e.
Place the cap on X0776 (EXT SIGNAL).
18
RCM - Sprayer Installation M anual for AGCO RoGator C-Series (RG900, RG1100, RG1300)

Advertisement

Table of Contents
loading

Related Products for RCm RG900

This manual is also suitable for:

Rg1100Rg1300