Connection to LA amplied controllers
Connection to LA amplied controllers
Enclosure drive capacity per amplied controller
Make sure the total number of connected enclosures does not exceed the maximum number of enclosures per controller
(refer to the footnotes).
Refer to the Amplication reference technical bulletin for the latest information on compatibility with amplied
controllers and cabling schemes for all enclosure types.
Kiva II
2 / 8 (SE), 2 / 4 (BTL)
SB15m
1 / 4 (SE), 1 / 2 (BTL)
Reduced maximum SPL or drive capacity with LA2Xi: refer to the LA2Xi owner's manual.
1
LA8 can drive up to two SB15m per output, but no more than six per controller at high level.
*
For passive loudspeakers, the value corresponds to the number of enclosures in parallel on the output. For active
loudspeakers, the value corresponds to the number of sections in parallel on the output.
82
LA2Xi
*
per output
/ total
per output
LA4X
LA8
*
/ total
per output
2 / 8
4 / 16
1 / 4
2 / 6
LA12X
*
*
/ total
per output
/ total
6 / 24
3 / 12
1
Kiva II owner's manual (EN) version 3.0