❺ Troubleshooting
• If a problem occurs, before you contact your retailer, please carry out these few simple checks
using the following tables.
• If the problem continues, contact your retailer.

5.1 I Appliance behaviour

• Use the flow switch to control the flow rate (see §2.4.4 Testing and adjusting the flow
• Check that the bottom plug hole is closed.
• Check that the diaphragm is not blocked and is not damaged or worn (see §4.3 I
The cleaner does not
• Clean the filter and empty the pump strainer (see §4.1 I Cleaning the filter pump's
move or moves slowly
• Make sure there is no air in the system. If the water level drops in the pump strainer
• Use the flow switch to control the flow rate (see §2.4.4 Testing and adjusting the flow
• Reduce the flow rate to distance the cleaner from the walls.
The cleaner's
• Check that the discharge nozzles are facing downwards (see §3.2 I Pool preparation).
movements do not cover
• Check that the hose has not become tangled or coiled. Lay them out in the sun to
the entire surface area of
the pool
• Check the position of the counterweights on the hose: 1 m from the cleaner.
• Check that the motor rotates freely inside the body of the cleaner.
• Check the length of the hose (see §2.2 I Assembling the hose sections).
The cleaner does not
• Check the position of the counterweights on the hose.
• Test and increase the flow rate if necessary (see §2.4.4 Testing and adjusting the flow
stay firmly on the pool
bottom
• Use the flow switch to control the flow rate (see §2.4.4 Testing and adjusting the flow
The cleaner gets stuck at
• Check the hose length. Shorten if necessary (see §2.2 I Assembling the hose sections).
the steps
• Use the discharge nozzles to guide the cleaner.
• Reposition the wheel deflector on the hose to provide better contact with the steps
The cleaner remains on
• Use the flow switch to guide you and reduce the flow rate by setting to position 2 (see
the walls or edges of the
pool.
• Check the position of the counterweights on the hose: 1 m from the cleaner.
The cleaner does not
• Use the flow switch to check that the flow rate corresponds to setting 3 (see §2.4.4
climb the walls (T5 Duo
only)
• Check the position of the counterweights on the hose: 1 m from the cleaner.
The cleaner goes beyond
the water line (T5 Duo
• Reduce the flow rate.
only)
rate).
Maintaining the diaphragm).
pre-filter).
or if you notice too many air bubbles in the pump strainer or leaving the discharge
nozzles, there is air in the system. Check the connections between the hoses, tighten
all connections on the pump and check that the O-ring of the pump strainer is not
worn.
rate).
stretch them if necessary.
rate).
rate).
and distance the cleaner.
§2.4.4 Testing and adjusting the flow rate).