Ff/Pa Module For Esk4-Ff/Pa / Ff/Pa Modul Für Esk4-Ff/Pa - KROHNE H250 M40 Service Manual

Hide thumbs Also See for H250 M40:
Table of Contents

Advertisement

3.3
FF/PA module for ESK4-FF/PA / FF/PA Modul für ESK4-FF/PA
Required components:
Installed ESK4 sensor module
FF or PA module
Module cover
Ribbon cable
Blind plugs to disable 4/20mA terminal
at ESK4
Terminal connector D/D-
1
2
Assembly:
Remove terminal connector 11/12 from
installed ESK4 and disable the 4/20mA
terminal by mounting the blind plugs (1)
Break out the perforated opening for the
ribbon cable from the ESK4 (2)
Insert the FF or PA module (3) in the 2nd
guiding slot of the module rack until it snaps
in
Connect FF/PA module and ESK4 with the
ribbon cable (4) and ensure that the cable is
properly fixed
Insert the module cover (5) in the 1
guiding slot of the rack
Plug in terminal connectors D/D-
Benötigte Komponenten:
Installiertes ESK4 Sensormodul
FF oder PA Modul
Modulabdeckung
Flachbandkabel
Blindstopfen zum Verschließen der
4/20mA Klemme am ESK4
Steckverbinder D/D-
3
4
5
Montage:
Steckverbinder 11/12 des installierten ESK4
entfernen und den 4/20mA Anschluss mit
Blindstopfen verschließen (1)
Perforierte Öffnung für das Flachbandkabel am
ESK4 (2) ausbrechen
FF oder PA Modul (3) in die 2. Führungsnut
des Modulträgers einschieben und einrasten
FF/PA Modul und ESK4 mit dem
Flachbandkabel (4) verbinden und festen Sitz
des Kabels prüfen
Modulabdeckung (5) in 1. und 3. Führungsnut
st
rd
and 3
einrasten.
Steckverbinder D/D- einstecken

Advertisement

Table of Contents
loading

This manual is also suitable for:

H250f m40H250 m40r

Table of Contents