Equipment category II 2G and II 2D, EPL Gb and Db
in protection type intrinsic safety "i"
© KROHNE 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 en
Supplementary instructions
Supplementary instructions
Supplementary instructions
Supplementary instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H250 M40 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for KROHNE H250 M40 Series

  • Page 1 H250 M40 H250 M40 H250 M40 Supplementary instructions Supplementary instructions Supplementary instructions Supplementary instructions Equipment category II 2G and II 2D, EPL Gb and Db in protection type intrinsic safety "i" © KROHNE 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 en...
  • Page 2: Table Of Contents

    4.4 Grounding and equipotential bonding................18 5 Operation 5.1 Start-up........................... 19 5.2 Operation ........................19 5.3 Electrostatic charge ....................... 19 6 Service 6.1 Maintenance ........................20 6.2 Dismantling ........................20 7 Notes www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 3: Safety Instructions

    The "X" after the certificate number refers to special conditions for safe use of the device, which have been listed in these instructions. If needed, the IEC certificate can be downloaded from the manufacturer's website. 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 4: Security Information

    The operator respectively his agent is responsible to follow further standards, directives or laws if required due to operating conditions or place of installation. This applies particularly for the use of easy detachable process connections such as SMS or Clamp when measuring flammable mediums. www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 5: Device Description

    8 Version Ex - Explosion-protected version 9 SIL Version SE - SIL compliant electronic signal output SK - SIL compliant limit switch * positions which are not needed are omitted (no blank positions) 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 6: Marking

    • AC - article code Additional plate The association of the housing cover to the device is confirmed by an additional plate with the serial number on the interior of the indicator part. www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 7: Flammable Products

    Definition of zone 21 acc. to EN 1127-1, Appendix B: An area in which an explosive atmosphere may occasionally occur in the form of a cloud of flammable dust in the air under normal operation. 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 8: Protection Types

    For the equipment category II 2 D and EPL Db, connection to an intrinsically safe circuit with protection level "ib" is required. When connecting the variable area flowmeter to an intrinsically safe circuit with protection level "ia", a higher protection level is given. www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 9: Ambient Temperature / Temperature Classes

    For device versions with a heating jacket the temperature of the heating medium does not • exceed the maximum permissible product temperature. For certain device version, lower values apply due to differing boundary conditions (e.g. lining materials). Here the user should consult the technical data sheet. 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 10 The permitted ambient temperature range is indicated on the nameplate; depending on the device version it is Tamb = -40...+65°C / -40...+149°F or Tamb = -25...+65°C / -13...+149°F. The minimum product temperature is -40°C / -40°F. www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 11 DN15 DN15 not admissible DN25 DN25 DN50 DN80 DN50 DN100 DN80 R1/R2 (Reed SPST) R1/R2 (Reed SPST) R1/R2 (Reed SPST) R1/R2 (Reed SPST) DN15 DN15 DN25 DN25 DN50 DN80 DN50 DN100 DN80 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 12 DN15 DN15 not admissible DN25 DN25 DN50 DN80 DN50 DN100 DN80 R1/R2 (Reed SPST) R1/R2 (Reed SPST) R1/R2 (Reed SPST) R1/R2 (Reed SPST) DN15 DN15 DN25 DN25 DN50 DN80 DN50 DN100 DN80 www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 13 ESK4 / ESK4-T ESK4-FF / ESK4-PA admissible K1/K2 - 64 mW / R1/R2 K1/K2 (I7S23,5-N / SC3,5-N0-Y) - 169 mW not admissible admissible K1/K2 (SJ3,5-SN bzw. SJ3,5-S1N) - 169 mW not admissible admissible 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 14 -40 ... +80 M40./../ESK4-T ESK4 and I/O modul -40 ... +52 -40 ... +67 -40 ... +77 M40./../ESK4-FF ESK4 and ESK4-FF -40 ... +36 -40 ... +51 -40 ... +76 M40./../ESK4-PA ESK4 and ESK4-PA www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 15: Surface Temperature For Equipment Category Ii 2D

    T85°C at an ambient temperature of 65°C / 149°F and a product temperature of 85°C / 185°F is valid without a dust coating. For higher product temperatures the maximum surface temperature is defined by the product. 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 16: Electrical Data

    Also, when operating the variable area flowmeter outside of the hazardous area, the connection must be made to an intrinsically safe circuit. When connecting to non-intrinsically safe circuits, there is a risk of damage to the safety-defining components. www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 17: Installation

    The manufacturer is not liable for any damage resulting from improper use or use other than the intended purpose. This applies in particular to hazards due to insufficient corrosion resistance and suitability of the materials in contact with product. 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 18: Electrical Connections

    Any existing cable shields should be connected to earth according to applicable installation regulations (EN 60079-14). A terminal connection in the terminal compartment permits a short way earthing of the cable shields. www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 19: Operation

    • spraying of electrons (e.g. in the vicinity of electrostatic painting systems). WARNING! Electrostatic charging of the housing surface by friction must be avoided. Variable area flowmeters must not be dry cleaned. 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 20: Service

    In the case of environmentally critical or hazardous products, appropriate safety precautions • must be taken with regard to residual liquids in the measuring unit. New gaskets have to be used when re-installing the device in the piping. • www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 21: Notes

    NOTES H250 M40 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 22 NOTES H250 M40 www.krohne.com 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02...
  • Page 23 NOTES H250 M40 02/2015 - 4001481102 - MA H250/M40-Exi--II2GD-AD R02 www.krohne.com...
  • Page 24 Measuring systems for the marine industry Head Office KROHNE Messtechnik GmbH Ludwig-Krohne-Str. 5 47058 Duisburg (Germany) Tel.:+49 203 301 0 Fax:+49 203 301 103 89 info@krohne.com The current list of all KROHNE contacts and addresses can be found at: www.krohne.com...

Table of Contents