2.4. Modes of Operation
Gas Leak Outdoors
(GLO)
Gas Leak Indoors
(GLI)
Confined Space
Monitor (CSM)
Purge
Search
Note: Pipeline Gas Test is an optional feature. When configured, it can be active in ALL
modes of operation, except for CSM.
2.5. Monitor Construction
Harness Clip
Semiconductor
Probe Connection
(Optional)
Base Screw
Gas Exhaust
Base Screw
49391
Revision 3
Used by technicians to investigate outdoor odour or leak
complaints and to pinpoint leaks. This mode supports the optional
Barhole feature.
Similar to the GLO mode, but without Barhole testing.
Used for confined space pre-entry testing and for personal
monitoring in potentially hazardous areas.
Used in gas and air purging applications.
Used to quickly find small leaks using a semiconductor sensor and
fast pump.
Figure 1: GS700 - Right View
Figure 2: GS700 - Left View
Gasurveyor 700
USER MANUAL
Visual Alarm
(360° LED bar)
Gas Inlet Nozzle
(with dust filter)
Charging Contacts
(Rechargeable only)
Visual Alarm
(360° LED bar)
Harness Clip
Buzzer
13