Supervisor level

Payment system lock

To avoid tampering, a programme lock
can be set up in programme opera-
tion. If the lock is applied, the pro-
gramme is interrupted and payment
credit is lost as soon as the door is
opened.
The time for the lock to be applied can
be adjusted to enable laundry to be ad-
ded.
- Factory default: off
- As soon as the programme starts
- 1–5 minutes after the start of the pro-
gramme

Delete paid signal

The "Paid" signal in coin box mode
can be applied until the end of the
programme or discarded if the pro-
gramme is not started after 5 minutes.
- Factory default: Off
- On

Debounce time

In coin mode, the debounce time for
the minimum payment signal that
must be applied can be adjusted.
- Factory setting: Short
For coin boxes where the falling coin
generates the paid pulse.
- Long
For central control units on a 230 V
basis.
78

Payment system overriding time

Setting the transition signal for the
coin box. Security time margin to pre-
vent the coin box being tampered
with.
The transition time can be adjusted in
15-minute increments between 30–
240 minutes or switched off.
If the programme does not end within
the transition period, the setting in the
coin box is reset. The programme is
cancelled.
Factory default: 180 minutes