Battery Test - Midtronics MDX-650 Instruction Manual

Battery conductance and electrical system analyzer
Hide thumbs Also See for MDX-650:
Table of Contents

Advertisement

MDX-650P
Battery Conductance &
System Analyzer
When you rst connect the tester to the battery, it functions as a voltmeter
until you press the ENTER button to start the test. This function can be turned
After you press ENTER, scroll to each parameter using the UP or DOWN
ARROW button and press ENTER to select. If any messages appear during the
test, see "Test Messages" on page 17.
1.
prompted to test the starting and charging systems.
IMPORTANT: The performance of the starting and charging systems depends
on the battery's condition. It is important that the battery is good and
fully charged before any further system testing.
4.
AGM SPIRAL, or
all rating systems are available for each application.
Standard
CCA
CA
MCA
JIS#
EN
DIN
SAE
IEC
www.midtronics.com

Battery Test

Scroll to and select
Scroll to and select
GEL where applicable.
Description
Cold Cranking Amps, as specified by SAE.
The most common rating for cranking
batteries at 0 ºF (–17.8 ºC).
Cranking Amps: Current available
at 32 ºF (0 ºC)
Marine Cranking Amps: Amount of current
available at 32 ºF (0 ºC)
Japanese Industrial Standard, shown on a
battery as a combination of numbers and letters.
Europa-Norm
Deutsche Industrie-Norm
Society of Automotive Engineers, the
European labeling of CCA
International Electrotechnical Commission
REGULAR
10
AGM FLAT PLATE ,
Range
100–2000
100-2000
100-2000
26A17 thru
245H52
100–2000
100–1200
100–2000
100–1200

Advertisement