Charging System Test; Charging System Test Results - Midtronics MDX-650 Instruction Manual

Battery conductance and electrical system analyzer
Hide thumbs Also See for MDX-650:
Table of Contents

Advertisement

MDX-650P
Battery Conductance &
System Analyzer
the battery test results and the message PRESS 8
8 ) button to proceed with the charging test.
Following the on-screen prompts:
1.
Rev the engine.
2.
Turn on high beams headlights and the blower fan.
3.
Rev engine with loads on.
4.
Idle engine and turn o loads.
5.
The Charging System
Alternator
Decision
Loads-off
DC Voltage
at rev

Charging System Test Results

Decision
NO PROBLEMS
NO OUTPUT
www.midtronics.com

Charging System Test

decision is displayed at the end of the procedure.
System is showing normal output from the alternator.
No alternator output detected.
Check all connections to and from the alternator,
especially the connection to the battery. If the
connection is loose or heavily corroded, clean or
replace the cable and retest.
If the belts and connections are in good working
condition, replace the alternator. (Older vehicles
use external voltage regulators, which may require
only replacement of the voltage regulator.)
14
DC Voltage
Interpretation
Press
Loads-on
at rev
continued