Battery Test - Midtronics MDX-650P Instruction Manual

Battery conductance and electrical system analyzer for 6 & 12-volt automotive starting batteries and 12 & 24-volt starting/charging systems
Hide thumbs Also See for MDX-650P:
Table of Contents

Advertisement

When you first connect the tester to the battery, it functions as a voltmeter
until you press the ENTER button to start the test. This function can be turned
off through the Options Menu
After you press ENTER, scroll to each parameter using the UP or DOWN
ARROW button and press ENTER to select. If any messages appear during the
test, see "Test Messages" on page 17.
BAT. LOCATION: Scroll to and select IN VEHICLE or OUT OF VEHICLE for a
1.
battery not connected to a vehicle. Following an IN VEHICLE test you will be
prompted to test the starting and charging systems.
IMPORTANT: The performance of the starting and charging systems depends
on the battery's condition. It is important that the battery is good and
fully charged before any further system testing.
2. POST TYPE: (In-Vehicle only) Scroll to TOP POST, SIDE POST or JUMP START
POST where applicable.
3. APPLICATION: Scroll to and select AUTOMOTIVE, MOTORCYCLE, MARINE,
LAWN & GARDEN, GROUP 31, or COMMERCIAL -4D/8D.
BATTERY TYPE: Scroll to and select REGULAR FLOODED, AGM FLAT PLATE ,
4.
AGM SPIRAL, or
STANDARD: Scroll to and select the battery's rating system. Not
5. BATTERY
all rating systems are available for each application.
Standard
CCA
CA
MCA
JIS#
EN
DIN
SAE
IEC
www.midtronics.com

Battery Test

GEL where applicable.
Description
Cold Cranking Amps, as specified by SAE.
The most common rating for cranking
batteries at 0 ºF (–17.8 ºC).
Cranking Amps: Current available
at 32 ºF (0 ºC)
Marine Cranking Amps: Amount of current
available at 32 ºF (0 ºC)
Japanese Industrial Standard, shown on a
battery as a combination of numbers and letters.
Europa-Norm
Deutsche Industrie-Norm
Society of Automotive Engineers, the
European labeling of CCA
International Electrotechnical Commission
11
MDX-650P
Battery Conductance &
System Analyzer
Range
100–2000
100-2000
100-2000
26A17 thru
245H52
100–2000
100–1200
100–2000
100–1200