Memory Card - Deckma Hamburg OMD-2005 Instruction Manual

Table of Contents

Advertisement

Main PCB with Holder
Terminals
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33
F1
F2
PE
PE
POWER
PILOT VOLT.
FLOW
STATUS
RES
24-240V IN
PILOT OUT
RES
L
N
PE
L
N
PE
A
B
PE
NO
1
2
3
4
5
6
7
8
9
10
Status LED's:
D7
Power ON
D11
Microprocessor (blinking)
D15
D12
Measuring Cell (blinking)
D16
D13
Display (blinking)
D17
D14
Spare
D18
D19
Alarm 1 OFF
D23
D20
Alarm 2 OFF
D24
D21
System Fault OFF
D25
D22
Spare
D26
13.1 Memory Card (refer to Fig. 6)
The Memory Card is located inside the door of the computer housing. It is
suitable for the life of the instrument, as it is calculated to the according MEPC
107(49) required storage time of at least 18 month. When the card is full, the
oldest entry will be overwritten, so that a replacement is not necessary. Under
normal use the card should not be taken out, as this is linked with the specific
system. The card can be read in other OMD-2005 units, but writing is only
possible in the related system.
If no Memory Card is mounted or a card from another system is mounted, the
unit will be in alarm conditions.
Issue: 27.05.08
DECKMA HAMBURG GmbH
Computerhousing
Logger /
Measuring
+
-
PE
PE
PE
Cell
Display
CLEAN
OUTPUT
ALARM 1
ALARM 2
SYSTEM FAULT
COM
NC
NO
COM
NC
NO
COM
NC
11
12
13
14
15
16
17
18
Status Separator
Status Water Supply
Spare
Status Datalogger
Alarm 1 ON
Alarm 2 ON
System Fault ON
Spare
Fig. 6
Instruction Manual OMD-2005
Protection Cover
Display PCB
Memory
Card
Page 22 of 25
Display PCB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents