(Refer to Fig. 3)
Connect the OMD-2005 Monitor to the sample point of the oily-water separator
outlet and to a source of oil free water employing 10 mm OD copper or stainless
steel pipe. The sample point should be located on a vertical section of the
separator outflow piping to minimize the effects of any entrained air. The tapping
point should be at a level above the outlet of the monitor to ensure the sample
cell is flooded at all times.
If connection to a vertical section of the separator outlet piping is impractical, the
tapping may be made into the side of the horizontal pipe. Avoid top or bottom
entry.
For separator discharge pipes up to 75 mm OD a standard "T"-type junction of
the welded or screwed type is satisfactory for the tapping point. For the separator
discharge pipes of 80 mm OD and above a sample probe should be employed
which protrudes into the discharge piping by approx. 25 % of the ID of the pipe.
Pressure relief valve
(if required)
Separator
Fig. 3
Issue: 27.05.08
DECKMA HAMBURG GmbH
Automatic
Stopping Device
To Bilge
OMD-2005
Oil Monitoring Device
ON
Alarm 1
Alarm 2
System
OK
DECKMA HAMBURG
www.deckma.com
10 X 1mm
Copper Tube
Outlet Separator
*
Inlet & Outlet connections R1/4" Female
Instruction Manual OMD-2005
Recirculating
Facilities
To Bilge
Vacuum breaker
*
Outlet
DE C K M A H AM B UR G
DH 7 5 4 5 0
Clean Water
Supply (Option)
To Bilge
Overboard discharge
Page 10 of 25