Sample Programming Session - Kaba 4000 User Manual

Table of Contents

Advertisement

6. If you make an error at any time, press <*> to cancel the command
(before pressing <#>).
7. Press <#>. The green LED should light for 1 second and the buzzer should sound
1 long and 2 short beeps to indicate acceptance of the programming command.
8. Enter another command, or press <#> to end the programming session.
For a complete list of command codes, refer to section 2.5.

2.4.3 Sample Programming Session

The following commands could all be performed in sequence in a single programming session,
or entered individually, starting with the Master Authorization code to open each programming
session.
1. Start the programming session (if the Master authorization code is 45657890).
#-4-5-6-5-7-8-9-0-#
2. Delete all existing Manager authorization and User access codes so that you can
change the code length to 6 digits for maximum security.
3-0-0-#
3. Define the Group 1 Manager authorization code (as 1176548). In this example,
the Master user makes an error when entering the code (enters 202 instead of 201),
and uses the <*> key to correct the mistake.
2-0-2-*-2-0-1-#-1-1-7-6-5-4-8-#
4. Define the access codes for Users 2, 3 and 4 in Group 1 (with codes 349023,
496756 and 090988).
2-1-2-#-3-4-9-0-2-3-#
2-1-3-#-4-9-6-7-5-6-#
2-1-4-#-0-9-0-9-8-8-#
5. Set the users in Group 1 as privileged users who can operate Passage Mode
and override or set a lockout.
9-6-1-#
6. Set the lock configuration to Handicapped.
8-0-2-#
4 0 0 0 P r o g r a m m a b l e E l e c t r o n i c P u s h b u t t o n L o c k • P K 2 9 7 1