EZCOM SETUP GUIDE

Step
Configure the VFD's parameters using the EZCOM parameter chart. Most of the parameters should already be
1
configured and only the ones highlighted in yellow should need to be changed.
Power down both VFD's and connect the 2-wire shielded cable to the corresponding SN & SP terminals as shown in
2
the EZCOM circuit wiring example on the next page. Be sure to add the RS485 termination jumper to the B hoist VFD
as shown on the EZCOM circuit wiring example.
Add the tandem activation circuit to digital input 6 on each VFD as shown in the EZCOM circuit wiring example on the
3
next page.
Power up the VFD's together at the same time and verify the communication is not disconnected by using the monitor
4
parameter db-08. If The value in db-08 = 9999 then troubleshooting is required.
5
Operate the hoists in tandem and individually and verify correct operation.

EZCOM PARAMETERS

Function
Digital Input 6 = Tandem Activation
EZCOM sync mode
EZCOM node ID
EZCOM communication error select
EZCOM communication time out
EZCOM communication wait time
EZCOM communication mode
EZCOM start node ID
EZCOM end node ID
EZCOM communication start method
EZCOM data size
EZCOM destination address 1
EZCOM destination register 1
EZCOM source register 1
EZCOM destination address 2
EZCOM destination register 2
EZCOM source register 2
EZCOM destination address 3
EZCOM destination register 3
EZCOM source register 3
Instruction
Parameter
CA-06
UE-43
1 = enabled speed + command
CF-02
0 = trip with error
CF-05
02 = prevent run / without error
CF-06
CF-07
CF-08
03 = EZCOM Administrator
CF-20
CF-21
00 = digital input 098:ECOM
CF-22
01 = always start on power up
CF-23
CF-24
CF-25
CF-26
CF-27
CF-28
CF-29
CF-30
CF-31
CF-32
Page 28
Hoist A
95
1
1.00 seconds
2 ms
1
2
3
2
480B
277E
2
480C
480D
2
480E
480F
Hoist B
95
1 = enabled speed + command
2
0 = trip with error
02 = prevent run / without error
1.00 seconds
2 ms
02 = EZCOM
1
2
00 = digital input 098:ECOM
01 = always start on power up
3
1
480B
277E
1
480C
480D
1
480E
480F