Multi-Speed 0; Multi-Speed And Acceleration/Deceleration Time - Hitachi SJ300-EL Series Instruction Manual Supplement

Inverter for elevator applications three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for SJ300-EL Series:
Table of Contents

Advertisement

2.2

Multi-speed and acceleration/deceleration time

Different acceleration and deceleration times can be set for each multistage speed. The acceleration
time is the one used between the current speed and target speed during acceleration. The deceleration
time is the one used between the current speed and creep speed (speed-7), or between the current
speed and the target speed during deceleration. Therefore use the deceleration time of A027 for creep
speed at stopping. Furthermore, inverter decelerates with the deceleration time that is set on that
multistage speed when the RUN command is removed.
Related parameters are shown in following table.
< Additional setting items>
Function Code
A020
F002
Acceleration time for multi-speed 0
F003
Deceleration time for multi-speed 0
A021
A221
Acceleration time for multi-speed 1
A321
Deceleration time for multi-speed 1
A022
A222
Acceleration time for multi-speed 2
A322
Deceleration time for multi-speed 2
A023
A223
Acceleration time for multi-speed 3
A323
Deceleration time for multi-speed 3
A024
A224
Acceleration time for multi-speed 4
A324
Deceleration time for multi-speed 4
A025
A225
Acceleration time for multi-speed 5
A325
Deceleration time for multi-speed 5
A026
A226
Acceleration time for multi-speed 6
A326
Deceleration time for multi-speed 6
A027
A227
Acceleration time for multi-speed 7
A327
Deceleration time for multi-speed 7
Function Name

Multi-speed 0

Multi-speed 1
Multi-speed 2
Multi-speed 3
Multi-speed 4
Multi-speed 5
Multi-speed 6
Multi-speed7 (creep speed)
Chapter 2 – Explanation of Functions
0.00, starting frequency-maximum.
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum.
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum.
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum.
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum.
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum.
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum.
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum.
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
10
Setting range
frequency(Hz)
frequency(Hz)
frequency(Hz)
frequency(Hz)
frequency(Hz)
frequency(Hz)
frequency(Hz)
frequency(Hz)

Advertisement

Table of Contents
loading

Table of Contents