4.Keyboard Description

4.1 Keyboard Indicators
Indicator flag
RUN
LOCAL/
REMOTE
FWD/REV
TUNE/TC
HzAV
4.2 Description of operation panel keys
Sign
Parameter
Setting /Esc
Key
Shift Key
Increasing Key
Decreasing Key
Running Key
Stop/Reset Key
Enter Key
Quick
Multifunction
Key
Keyboard
Encoder

5.Standard specifications

Items
Rated voltage
Input AC voltage
frequency
Allowing DC
voltage fluctuations
Control system
Control method
Automatic torque
boost function
Acceleration/deceler
ation control
V/F curve mode
Over load capability
Maximum frequency
Carrier Frequency
Input frequency
resolution
Start torque
Speed range
Steady-speed precision
Torque response
Torque boost
Jogging control
Diagram 4-1:Operation panel display
Running indicator light
*ON: the inverter is working *OFF: the inverter is stops
Command indicator light ,That is the indicator for keyboard operation,
terminal operation and remote
operation(communication control)
*ON: terminal control working status
*OFF: keyboard control working status
*Flashing: Remote control working status
Forward/reverse running light
*ON: in forward status *OFF: in reversal status
Motor self-learning/Torque control/Fault indicator
*Slow flashing: in the motor tunning status
*Quick flashing: in the fault status
Name
* Enter into the modified status of main menu
* Esc from functional parameter modification
* Esc submenu or functional menu to status menu
* Choose displayed parameter circularly under running or stop
interface; choose parameter's modified position when modify parameter.
* Parameter or function number increasing, set by parameter F6.18.
* Parameter or function number decreasing, set by parameter F6.19.
* For starting running in the mode of keyboard control status.
* For stopping running in the running status; for resetting the operation
in the fault alarm status .the function of the key is subject to F6.00
* Enter the menu screen step by step, set the parameter confirmation
*This key function is determined by the function code F6.21
* F0.03 setting to 4, and the keyboard potentiometer setting the
operating frequency.
AC 1PH 220V(-15%)~220V(+10%);
AC 3PH 220V(-15%)~220V(+10%);
AC 3PH 380V(-15%)~380V(+10%);
AC 3PH 480V(-10%)~480V(+10%);
50Hz/60Hz
G1/G2:DC 150~450V;
G3:DC 250~800V
G4:DC 400~900V
High performance vector control inverter based on DSP
V/F control, vector control W/O PG
Realize low frequency (1Hz) and large output torque control under the V/F
control mode.
Straight or S-curve mode. Four times available and time range is
0.0~6500.0s.
Linear, square root/m-th power, custom V/F curve
G type: rated current 150% - 1 minute, rated current 180% - 2 seconds
1.Vector control:0~300Hz;
0.5~16kHz; automatically adjust carrier frequency according to the load
characteristics.
Digital setting: 0.01Hz Analog setting: maximum frequency×0.025%
G type: 0.5Hz/150% (vector control W/O PG)
1:100 (vector control W/O PG)
Vector control W/O PG: ≤ ± 0.5% (Rated synchronous speed)
≤ 40ms (vector control W/O PG)
Automatic torque boost; manual torque boost 0.1%~30.0%
Jog Frequency Range: 0.00Hz~max. frequency;
Jog Ac/deceleration time: 0.0s~6500.0s
Name
Hz
Frequency unit
A
Current unit
V
Voltage unit
RPM
Speed unit
%
Percentage
Function
Specifications
2.V/F control:0~3200Hz