QUICK START
3.2.2 FIRST OPERATION
 The first line in the front display indicates the actual output voltage and current.
The second line shows the settings of the controls.
 Check the text 'front' is indicated - this means the unit is in local-operation and
can be controlled by the V-knob and A-knob at the front panel.
 Switch the output on by pressing the on/OFF button.
 Turn the V- and A-knob a half turn clockwise. Depending on the load, a voltage
should now be present on the output and a current will run through the load.
 Depending on the load and settings, the unit will be either in constant voltage or
constant current mode, respectively CV- or CC-mode.
 Respectively the indication 'CV' will appear on the first line, next to the actual
voltage value. The indication 'CC' will appear next to the actual current value.
3.2.3 LIMITATION OF SETTINGS
 By default, the settings for CV and CC Limit are set to the maximum.
 Change the limit settings via Menu > Protection > Limits.
3.2.4 REMOTE PROGRAMMING
 By default a unit is in local operation, see fig. 3 - 4.
 In remote operation different programming options are available such as 'eth',
'web', 'seq', 'slot1', etc.
 Via the front menu the source can be set to the required programming input via:
Menu > Configuration > Source.
 When connected to LAN, enter the unit's IP-address in a web browser to open
the web interface.
 With this interface all above described
parameters plus additional parameters can be set
and read.
 For more information, see the chapter Remote
Programming of the user manual.
3.3
Download User Manual
3.3.1 FULL VERSION
Check at www.DeltaPowerSupplies.com for
the full version of the user manual via:
Products > SM3300 >
3.4
Driver & Example Software
3.4.1 APPLICATIONS & INTERFACES
 Check at www.DeltaPowerSupplies.com for
driver and example software via:
Products > SM3300 > Downloads.
Note:
It is strongly recommended to regularly check for updates
for additional functionality and improvements.
7 / 30
Downloads.
DELTA ELEKTRONIKA B.V.
fig 3 - 5 The front console of the web interface for setting of the output
and monitoring various parameters.
fig 3 - 6 Regularly check for new versions of
user manual and firmware.
actual voltage
actual current
set voltage
set current
indicator for CV-mode, for CC-mode
local operation
fig 3 - 3 Start up settings.
local operation
CV-mode
fig 3 - 4 Output power is 19W.
rev. Jan. 2022
SM3300

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sm18-220Sm66-ar-110Sm100-ar-75Sm330-ar-22Sm660-ar-11

Table of Contents