Summary of Contents for Delta Elektronika SM 30-200

  • Page 1 SM 6000 - se ries SM 15-400 • SM 30-200 • SM 45-140 • SM 60-100 • SM 70-90 • SM 120-50 • SM 300-20 • Elso Philips Service Jilemnického 2; 911 01 Trenèín tel: +421 32 6582410, 7431690 fax:...
  • Page 2 Parts Substitutions & Modifications Parts sub sti tu tions and mod i fi ca tions are al lowed by au tho rized Delta Elektronika ser vice per son nel only. For re pairs or mod ifications the unit must be re turned to a Delta Elektronika ser vice facility.
  • Page 3 DELTA ELEKTRONIKA BV SM6000 Environmental Conditions The Delta Elektronika power supplies safety approval applies to the following operating conditions: • Indoor use • : −20 to 50 °C Ambient temperature • Maximum relative humidity : 95%, non condensing, up to 40 °C : 75%, non condensing, up to 50 °C...
  • Page 4: Ripple & Noise

    SM6000 DELTA ELEKTRONIKA BV DESCRIPTIONS OUT PUT SM 15-400 SM 30-200 The SM15-400, SM30-200, SM45-140, SM60-100, SM70-90, SM120-50 and SM300-20 can ei ther be used as a con stant volt age source with cur rent limiting or as a con stant cur rent source with voltage lim iting.
  • Page 5: An A Log Pro Gramming

    Ethernet / IEEE488 / RS232 PRO GRAMMING The Delta Elektronika PSC-ETH, PSC-488 and the PSC-232 con trol lers can be built in side the unit. Voltage and cur rent can easily be pro grammed and read back. Also all the status outputs can be read by the computer.
  • Page 6 SM6000 DELTA ELEKTRONIKA BV fig. 3 - 8 Location of out put terminals and an alog prog. con nector on rear panel CON A In ter lock Con nec tor CON B Master connector for Mas ter / Slave op eration (out put)
  • Page 7 DELTA ELEKTRONIKA BV SM6000 RE MOTE SHUT DOWN (RSD) A volt age of +4 V...+12 V on the Re mote Shut Down in put on the programming con nector CON E will switch off the out put of the unit.
  • Page 8: Hold - Up Time

    SM6000 DELTA ELEKTRONIKA BV RFI SUP PRES SION Both the in put and out put have RFI fil ters, re sulting in very low conducted RFI to the line and load. Due to the out put fil ter the output voltage is very clean, hav ing al most no spikes.
  • Page 9: Series Operation

    DELTA ELEKTRONIKA BV SM6000 SERIES OP ER A TION Series op eration is al lowed up to 600 V total voltage. The power sup plies can be con nected in se ries without spe cial pre cautions. For eas ier con trol, Mas ter / Slave op eration is recommended (see fig. 3- 18).
  • Page 10 SM6000 DELTA ELEKTRONIKA BV VOLTAGE AND CUR RENT LIMIT The Voltage Limit will pro tect your circuit from un wanted high voltages. A high out put volt age could be caused by ac ci den tal in ter rup tion of leads, ac ci den tally turning up the voltage potmeter, a pro gramming er ror or a de fect in the power supply.
  • Page 11: Operating The Unit For The First Time

    DELTA ELEKTRONIKA BV SM6000 OPERATING MANUAL OPERATING THE UNIT FOR THE FIRST TIME Check there is no con densation on the unit. If there is, al low some • time to dry. Check there is a link be tween + and S+ and be tween – and S– on •...
  • Page 12 SM6000 DELTA ELEKTRONIKA BV Connect the pro gramming voltage source(s) (0 - 5 V) to the • analog pro gramming con nector CON E on the rear panel (see fig. 4 - 2 and fig. 4 - 3). Al ways use a shielded ca ble (max. 30 me ter) for pro gram ming.
  • Page 13: Battery Charger

    DELTA ELEKTRONIKA BV SM6000 Max. 2 V per load lead can be compensated. • Suggested circuit breakers for pro tection power sup ply Note that the voltage drop in the leads de creases the max. Model Type num ber Brand Re marks output voltage rat ing.
  • Page 14: Master / Slave Par Al Lel Op Er A Tion

    SM6000 DELTA ELEKTRONIKA BV If DIP switch 4 of SW1 is op erated when the unit is turned on, the out put will shutdown to avoid accidental dam age. The max. num ber of slaves is only limited by the max.
  • Page 15: Operating And Storage Conditions

    DELTA ELEKTRONIKA BV SM6000 OPERATING AND STORAGE CONDITIONS TEM PER A TURE The op erating tem perature range at full load is –20 to +50 °C. • But this tem perature range only holds when the AIR-INTAKE and AIR-OUTLET are un obstructed and the temperature of the AIR-INTAKE is not higher than +50 °C.
  • Page 16: Troubleshooting

    SM6000 DELTA ELEKTRONIKA BV TROUBLE SHOOTING GEN ERAL In case you need as sistance for re pairing a unit, please con tact • our en gineers us ing the ad dress "Support@Delta-Elektronika.nl". In case you want us to re pair the unit, please first fill out the •...
  • Page 17 DELTA ELEKTRONIKA BV SM6000 MASTER / SLAVE PAR ALLEL PROB LEMS Check the voltage drop of the wir ing be tween the master and the • slaves is < 10 mV. Check the wiring has a low in ductance. •...
  • Page 18: Meter Calibration

    SM6000 DELTA ELEKTRONIKA BV CALIBRATION GEN ERAL The power supplies are factory calibrated • and nor mally need no further cal ibration. Only in spe cial sit u a tions (for ex am ple af ter repairing a unit) calibration can be nec es- sary.
  • Page 19 P.O. BOX 27 4300 AA ZIERIKZEE The Neth er lands de clare un der sole re spon si bil ity that the fol low ing Power Sup plies: SM 15-400 SM 30-200 SM 45-140 SM 60-100 SM 70-90 SM 120-50 SM 300-20 meet the in tent of Di rectives 2004/108/EC;...