Delta Elektronika SM 15-100 Product Manual

Delta Elektronika SM 15-100 Product Manual

Sm1500 series
Hide thumbs Also See for SM 15-100:

Advertisement

DELTA ELEKTRONIKA B.V.
DC POWER SUPPLIES
SM1500-se ries
SM 15-100
SM 35-45
SM 52-30
SM 52-AR-60
SM 70-22
SM 120-13
SM 300-5
SM 400-AR-8
PROD UCT MAN UAL
Con tents:
1 - Datasheet
2 - Safety Instructions
3 - General
4 - Installation
5 - Trouble Shooting
6 - Maintenance & Calibration
7 - EU Declaration
Vissersdijk 4, 4301 ND
www.DeltaPowerSupplies.com
Zierikzee, the Netherlands
Tel. +31 111 413656

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SM 15-100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Delta Elektronika SM 15-100

  • Page 1 Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com DELTA ELEKTRONIKA B.V. Zierikzee, the Netherlands Tel. +31 111 413656 DC POWER SUPPLIES SM1500-se ries SM 15-100 • SM 35-45 • SM 52-30 • SM 52-AR-60 • SM 70-22 • SM 120-13 • SM 300-5 •...
  • Page 2: Ac Input Ratings

    Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and intended use of this equipment and may impair the built-in protections. Delta Elektronika shall not be liable for user’s failure to comply with these requirements.
  • Page 3 Unscrew the screws and remove the cover(s). • Always place the cover(s) back before connecting the unit to the mains supply again. 10 Environmental Conditions The Delta Elektronika power supplies safety approval applies to the following operating conditions: • Indoor use •...
  • Page 4: Input Voltage

    SM1500 GENERAL 3 GENERAL SM 15-100 SM 35-45 OUT PUT The SM15-100, SM35-45, SM52-30, SM52-AR-60, SM70-22, SM120-13, SM300-5 and the SM400-AR-8 can ei ther be used as a con stant volt age source with cur rent lim it ing or as a con stant cur rent source with volt age lim it - ing.
  • Page 5: An A Log Pro Gramming

    ETHERNET / IEEE488 / RS232 PRO GRAMMING The Delta Elektronika PSC-ETH, PSC-488 and the PSC-232 con trol lers can be built in side the unit. Volt age and cur rent can eas ily be pro grammed and read back. Also all the sta tus out puts can be read by the com puter.
  • Page 6 Sta tus re lay out puts on CON D. out put, clos est to SW1. This sit u a tion gives the re lay po si tions dur ing fault con di tion. rev. August 2018 DELTA ELEKTRONIKA B.V. Page 3 - 3...
  • Page 7 In su la tion test voltages ers) be tween in put and out put is tested at 3750 Vrms dur ing 1 min - ute. This is tested be fore as sem bly. Page 3 - 4 DELTA ELEKTRONIKA B.V. rev. August 2018...
  • Page 8: Remote Sensing

    2.5 V. Mas ter / Slave se ries op er a tion For sens ing on a pul sat ing load, see par. 20) of this chap ter. rev. August 2018 DELTA ELEKTRONIKA B.V. Page 3 - 5...
  • Page 9: Series Operation

    Con nect CON C to Mas ter. Con nect CON B to Slave2. Warn ing: Never con nect CON C to CON C ! See page 4 - 3 for more de tails. Page 3 - 6 DELTA ELEKTRONIKA B.V. rev. August 2018...
  • Page 10 Note: The con trol cir cuit makes the fan start in a pul sat ing mode, dur ing which pe riod it can pro duce a high pitched sound. This is nor mal. DI MEN SIONS rev. August 2018 DELTA ELEKTRONIKA B.V. Page 3 - 7...
  • Page 11: Installation

    By press ing the DIS PLAY CV/CC SETTING but ton, the me ters • will show the set ting of the CV and CC po ten ti om e ter. Page 4 - 1 DELTA ELEKTRONIKA B.V. rev. August 2018...
  • Page 12: Key Lock

    Use CON H in stead. The pin ning of CON H is equal to the pin ning of CON E. For fur ther op er at ing in struc tions, see pre vi ous para graph 6). • rev. August 2018 DELTA ELEKTRONIKA B.V. Page 4 - 2...
  • Page 13: Battery Charger

    4 - 8). The cir cuit breaker should have a DC volt age rat - ing twice the bat tery volt age. Use the very fast type (Z), a Page 4 - 3 DELTA ELEKTRONIKA B.V. rev. August 2018...
  • Page 14: Re Mote Shutdown

    M/S par al lel mode. In this mode the fig. 4 - 12 DCF LED, DCF re lay and DCF sta tus on the slaves are Mas ter / Slave mixed se ries - par al lel connections rev. August 2018 DELTA ELEKTRONIKA B.V. Page 4 - 4...
  • Page 15 CV-potmeter must be fully opened. Note: A Mas ter / Slave com bi na tion can al ways be • pro grammed, also with the IEEE488/RS232 con trol ler (PSC-448/PSC-232 (both δ-prod ucts) Page 4 - 5 DELTA ELEKTRONIKA B.V. rev. August 2018...
  • Page 16: Troubleshooting

    To check the fuse mea sure the volt age be tween Ø and the mi nus out put, a high volt age means too much cur rent flow ing through the fuse. F27_2 = 650 mA, self re set ting. rev. August 2018 DELTA ELEKTRONIKA B.V. Page 5 - 1...
  • Page 17 5) in "op er at ing man ual". OTHER If the prob lem per sists, please fill out the RMA-form on our • website www.DeltaPowerSupplies.com. See pre vi ous para graph Page 5 - 2 DELTA ELEKTRONIKA B.V. rev. August 2018...
  • Page 18: Maintenance And Calibration

    Warn ing! Wrong cal i bra tion can dam age the unit. fig. 6 - 3 Cal i brating max. cur rent and off set on P650. rev. August 2018 DELTA ELEKTRONIKA B.V. Page 6 - 1...
  • Page 19 SM1500 EU DECLARATION DELTA ELEKTRONIKA B.V. Vissersdijk 4, 4301 ND www.DeltaPowerSupplies.com Zierikzee, the Netherlands Tel. +31 111 413656 DC POWER SUPPLIES EU Dec la ra tion of Con for mity - SM1500-series Delta Elektronika Vissersdijk 4 4301 ND ZIERIKZEE The Neth er lands...