Summary of Contents for Delta Elektronika SM 15-400

  • Page 1 SM 6000 series SM 15 - 400 SM 30 - 200 SM 45 - 140 SM 60 - 100 SM 70 - 90 SM 120 - 50 SM 300 - 20 SM 600 - 10...
  • Page 2: Safety Instructions

    Failure to comply with the safety precautions or warnings in this document violates safety standards of design, manufacture and intended use of this equipment and may impair the built-in protections within. Delta Elektronika shall not be liable for user’s failure to comply with these requirements.
  • Page 3: Input Ratings

    Parts Substitutions & Modifications Parts sub sti tu tions and mod i fi ca tions are al lowed by au tho rized Delta Elektronika ser vice per sonnel only. For repairs or mod ifications the unit must be re turned to a Delta Elektronika ser vice facility.
  • Page 4: Environmental Conditions

    SM6000 DELTA ELEKTRONIKA BV Environmental Conditions The Delta Elektronika power supplies safety approval applies to the following operating conditions: • Indoor use : −20 to 50 °C • Ambient temperature Maximum relative humidity : 95%, non condensing, up to 40 °C •...
  • Page 5: Input Voltage

    SM6000 DELTA ELEKTRONIKA BV DESCRIPTIONS OUT PUT SM 15-400 SM 30-200 The SM15-400, SM30-200, SM45-140, SM60-100, SM70-90, SM120-50, SM300-20 and SM600-10 can ei ther be used as a con stant volt age source with current limiting or as a con stant cur rent source with voltage lim iting.
  • Page 6: An A Log Pro Gramming

    ETH / IEEE488 / RS232 / CAN / PROFI PRO GRAM MING The Delta Elektronika PSC-ETH, PSC-488, PSC-232, PSC CAN and PSC PROFI con trollers can be factory in stalled in side the unit. Voltage and cur rent can easily be pro grammed and read back. Also all the status outputs can be read by the computer.
  • Page 7 SM6000 DELTA ELEKTRONIKA BV fig. 3 - 8 Location of out put terminals and an alog prog. con nector on rear panel CON A In ter lock Con nec tor CON B Master connector for Mas ter / Slave op eration (out put)
  • Page 8 DELTA ELEKTRONIKA BV SM6000 RE MOTE SHUT DOWN (RSD) A volt age of +4 V...+12 V on the Re mote Shut Down in put on the programming con nector CON E will switch off the out put of the unit.
  • Page 9: Phase Loss

    SM6000 DELTA ELEKTRONIKA BV RFI SUP PRES SION Both the in put and out put have RFI fil ters, re sulting in very low conducted RFI to the line and load. Due to the out put fil ter the output voltage is very clean, hav ing al most no spikes.
  • Page 10: Series Operation

    DELTA ELEKTRONIKA BV SM6000 SERIES OP ER A TION Series op eration is al lowed up to 600 V total voltage. The power sup plies can be con nected in se ries without spe cial pre cautions. For eas ier con trol, Mas ter / Slave op eration is recommended (see fig. 3- 18).
  • Page 11 SM6000 DELTA ELEKTRONIKA BV VOLTAGE AND CUR RENT LIMIT The Voltage Limit will pro tect your circuit from un wanted high voltages. A high out put volt age could be caused by ac ci den tal in ter rup tion of leads, ac ci den tally turning up the voltage potmeter, a pro gramming er ror or a de fect in the power supply.
  • Page 12: Operating The Unit For The First Time

    DELTA ELEKTRONIKA BV SM6000 OPERATING MANUAL OPERATING THE UNIT FOR THE FIRST TIME Warn ing: care fully read the chap ter "Safety In structions" in this man ual be fore op erating the unit! Check there is no con densation on the unit. If there is, al low some •...
  • Page 13 SM6000 DELTA ELEKTRONIKA BV switch on will be the same as be fore switching the mains volt age off. AN A LOG PRO GRAMMING Set DIP switch 1 of SW1 in po sition UP to se lect CON E for pro- •...
  • Page 14: Battery Charger

    DELTA ELEKTRONIKA BV SM6000 STATUS OUT PUTS cir cuit break ers for pro tection power sup ply Sug gested The status outputs have a separate Ø con nection (pin 8) to avoid • Model Brand Re marks Type num ber unwanted offsets in the pro gramming.
  • Page 15: Master / Slave Par Al Lel Op Er A Tion

    SM6000 DELTA ELEKTRONIKA BV After turning the units on again, the slaves will be in Re mote CV • mode and the Keylock (see pre vious paragraph 2) is ac tivated. This is be cause the unit au tomatically de tects the presence of the RJ45 con nec tor in CON C (if this ca ble is con nected to an other unit).
  • Page 16: Operating And Storage Conditions

    DELTA ELEKTRONIKA BV SM6000 OPERATING AND STORAGE CONDITIONS TEM PER A TURE The op erating tem perature range at full load is –20 to +50 °C. • But this tem perature range only holds when the AIR-INTAKE and AIR-OUTLET are un obstructed and the temperature of the AIR-INTAKE is not higher than +50 °C.
  • Page 17: Troubleshooting

    SM6000 DELTA ELEKTRONIKA BV TROUBLE SHOOTING GEN ERAL In case you need as sistance for re pairing a unit, please con tact • our en gineers us ing the ad dress "Support@Delta-Elektronika.nl". In case you want us to re pair the unit, please first fill out the •...
  • Page 18 DELTA ELEKTRONIKA BV SM6000 MASTER / SLAVE PAR ALLEL PROB LEMS Check the voltage drop of the wir ing be tween the master and the • slaves is < 10 mV. Check the wiring has a low in ductance. •...
  • Page 19: Meter Calibration

    SM6000 DELTA ELEKTRONIKA BV CALIBRATION GEN ERAL The power supplies are factory calibrated • and nor mally need no further cal ibration. Only in spe cial sit u a tions (for ex am ple af ter repairing a unit) calibration can be nec es- sary.
  • Page 20 Vissersdijk 4 Tel. +31 111 413656 4301 ND Zierikzee Fax. +31 111 416919 The Netherlands www.deltapowersupplies.com DELTA ELEKTRONIKA B.V. EC Dec la ra tion of Con for mity Delta Elektronika Vissersdijk 4 4301 ND ZIERIKZEE The Neth er lands De clare un der sole re spon si bil ity that the fol low ing Power Sup plies:...