Lcd Display References - Viking I-770 Installation Instructions And Safety Information

Single and dual gate systems
Table of Contents

Advertisement

TROUBLESHOOTING
The Control Board is equipped with a LCD Display that provides operator information,
current conditions, settings, diagnostics and error messages. Use the table below to
identify the corresponding "TS Ref#". Refer to pages 36-41 for further troubleshooting.
Meaning
LCD MSG
MODEL
Indicates the Model of the unit. I-770
i770
System Status Messages
GATE IS
Gate is stopped between limits.
IDLE
GATE IS
Gate is opening.
OPENING
GATE IS
Gate is closing.
CLOSING
GATE IS
Gate is at the limit open position.
OPENED
GATE IS
Gate is at the limit close position.
CLOSED
STOP BY
Primary or Single motor has stopped due to an obstruction of the gate system.
Also refer to the "ODS" LED. (pg 24, 26, 36 @ #4, 37 @ #18)
OBSTRUCT
STOP BY
Primary or Single motor has stopped due to an overload of the gate system.
Also refer to the "ODS" LED. (pg 24, 26, 36 @ #4, 37 @ #18)
OVERLOAD
OVERLAP
Gate is waiting for the overlap time.
TIMING
HOLDING
Gate is at the limit open position and timing to close - The display shows the
actual time left before closing.
__ SEC
STOP BY
Secondary motor has stopped due to an obstruction sensor event. Also refer to
the "DIAGNOSE" LED on the Secondary Module. (pg 24, 26, 36 @ #4, 37 @ #S1)
ODS
S
RED CONN
The Motor Connector is not plugged into the red Open Left or Open Right
socket at the Control Board. (pg 11, 20)
UNPLUGED
3 8

LCD Display References

Press the Diagnose button to manually scroll
through all of the Messages.
NOTE:
Error Messages will be displayed first.
The "Diagnose" LED will flash consecutively
indicating how many Error Messages are
available.
VIKING TECHNICAL SUPPORT 1.800.908.0884
Page 41
TS Ref #s
11, 12,
13
11, 12
11, 12,
13
21