Lcd Display References - Viking F-1NX Installation Instructions And Safety Information

Table of Contents

Advertisement

TROUBLESHOOTING

LCD Display References

The control board is equipped with a LCD Display that provides operator information,
current conditions, settings, diagnostics and error messages. Use the table below to
identify the corresponding "TS Ref#" and refer to page 41 for further troubleshooting.
Meaning
LCD MSG
VIKING
Welcome Message
ACCESS
MODEL
Indicates the Model of the unit
F1
System Status Messages
GATE IS
Gate is stopped between limits
IDLE
GATE IS
Gate is opening
OPENING
GATE IS
Gate is closing
CLOSING
GATE IS
Gate is at the limit open position
OPENED
GATE IS
Gate is at the limit close position
CLOSED
STOP BY
Gate stopped due to an obstruction sensor event
OBSTRUCT
STOP BY
Gate stopped due to an overload of the gate system
OVERLOAD
OVERLAP
Gate is waiting for the overlap time
TIMING
HOLDING
Gate is at the limit open position and timing to close - The display shows
the actual time left before closing
__ SEC
UL LEARN
Indicates the number of connected Monitored Entrapment Protection
Sensors that are being monitored. NO LEARN = no sensors learned. (pg 11)
UL_ RO_
3 8
1. Error Messages will be displayed first.
2. The "Diagnose" LED will flash consecutively
indicating how many Error Messages are
available.
3. Press the Diagnose button to manually
scroll through all of the Messages.
VIKING TECHNICAL SUPPORT 1.800.908.0884
Page 41
TS Ref #s
11, 12,
13, 22
11, 12

Advertisement