Braking system
ACTIVATION screen page
On this screen, you can delete the errors from the
memory of the controller and you can enable some
systems controlled by the control unit.
P.A.D.S. characteristic.
ABS Warning Light
ERRORS screen page
This display shows potential errors detected in the
vehicle (ATT) or stored in the control unit (MEM)
and it allows to check error clearing (STO).
Description
Front wheel speed sensor: electrical diagnosis
Front wheel speed sensor: functional diagnosis
Rear wheel speed sensor: electrical diagnosis
Rear wheel speed sensor: functional diagnosis
Comparison between the front and rear wheel speed
Internal error: fault at the front circuit input electric valve
Internal error: fault at the front circuit output electric valve
Internal error: fault at the rear circuit input electric valve
Internal error: fault at the rear circuit output electric valve
Internal error: fault at the recirculation pump
Internal error: fault at the electric valve relay
Internal error: fault at the control unit
Low power supply voltage
High power supply voltage
Encoding error
CAN error: controller error
CAN error: line failure (busoff)
CAN error: failed reception at the instrument panel
CAN error: failed reception at the injection control unit
BRAK SYS - 476
ACTIVATIONS
Value/example
Units of
measure
ment
ERRORS
Code
C1033
short circuit to positive / short circuit to negative / open
C1034
C1031
short circuit to positive / short circuit to negative / open
C1032
C1024
C1054
C1049
C1052
C1048
C1015
C1014
C1021
C1058
C1059
C1089
U2921
U2922
U2924
U2925
RSV4 RR-RF
Notes
Symptom
circuit
Signal not plausible
circuit
Signal not plausible
excessive difference
fault at the front circuit input electric valve
fault at the front circuit output electric valve
fault at the rear circuit input electric valve
fault at the rear circuit output electric valve
fault at the recirculation pump
fault at the electric valve relay
fault at the control unit
low voltage
high voltage
-
controller error
line failure (busoff)
failed reception at the instrument panel
failed reception at the injection control unit