Electrical system
•
key code read but not recognised
Error cause
•
The read code is not stored in the instrument panel memory
Troubleshooting
•
Carry out key data storage procedure
B0004 Immobilizer fault
•
read key code not read (key not present or transponder not working)
Error cause
•
Key transponder does not communicate its own code
Troubleshooting
•
Replace the key
B0005 Immobilizer fault
•
Immobilizer fault: aerial not working (open or short-circuited)
Error cause
•
An electric interruption or a ground short circuit or voltage to the circuit have been detected
Troubleshooting
•
Check the sensor connector on the cable harness and the instrument panel connector. If
not OK, restore; if OK, check electrical characteristics and aerial circuit continuity from the
instrument panel connector on PIN 2 and 3: if not OK, restore cable harness; if OK, check
circuit ground insulation: if not ground insulated, restore cable harness; if insulated, with key
ON, with instrument panel connector disconnected, check that there is not voltage at the
circuit ends: if there is voltage, restore the cable harness
B0006 Internal controller fault
Error cause
•
There is a fault in the instrument panel
Troubleshooting
•
Replace the instrument panel
System not programmed
Storing new keys
NOTE
REGARDLESS OF THE LANGUAGE SET IN THE DASHBOARD FUNCTIONS, THE KEY PRO-
GRAMMING PROCEDURE CAN ONLY BE VIEWED IN ENGLISH.
ELE SYS - 130
RSV4 RR-RF